WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have nished.

8. Conversion to LP Gas

Check the 'Technical Data' section at the back of the book
that the hob is convertible to the gas you want to use.
A suitably competent person must perform the conversion.
After conversion the installation must comply with the
relevant regulations and also the local electricity supply
company requirements. Read the instructions before
converting this appliance.
Failure to convert the appliance correctly could
n
n
invalidate any warranty or liability claims and lead
to prosecution.
When servicing or replacing gas-carrying
n
n
components disconnect from the gas supply before
starting operation. Check the appliance is gas sound
after completion.
DO NOT use reconditioned or unauthorised gas
n
n
controls.
Disconnect from the electricity and gas supply
n
n
before servicing.
Before electrical reconnection, check that the
n
n
appliance is electrically safe.

Injectors

Remove the burner caps and heads. Remove the old jets
(Fig.8-1). Fit the new jets (see the 'Technical Data' section at
the back of this book for the correct jets). Reassemble in the
reverse order.

Tap Adjustment

Removing the Handrail
Remove the handrail. Now remove the 2 cross-headed screws
hidden behind the handrail end brackets (Fig.8-2).
Removing the Control Panel
Pull o all the control knobs and remove the xing screws
underneath the control panel.
Lift the control panel and pull forwards, taking care not to
damage or strain the wiring.
Remove the two screws holding the shield in front of the
control taps and remove the shield (Fig.8-3).
Bypass Screw Adjustment
Turn the bypass screw on each control clockwise to the stop
(Fig.8-4). Re t the control panel.
A
ArtNo.311-0010 Injectors
A – Jet, B – Internal injector, C – External injector
Art No 215-0028 - Handrail fascia fixings
ArtNo.0102-0011 - Screwing
the control valve bypass screw
27
Fig.8-1
B
C
Fig.8-2
Fig.8-3
Fig.8-4