Installation / Performance Check List - Nordyne TC Series User Manual

Two-stage condensing gas furnaces with fixed & variable speed blowers
Table of Contents

Advertisement

ATTENTION INSTALLERS:
It is your responsibility to know this product better than your customer.
This includes being able to install the product according to strict
safety guidelines and instructing the customer on how to operate
and maintain the equipment for the life of the product. Safety should
always be the deciding factor when installing this product and us-
ing common sense plays an important role as well. Pay attention to
all safety warnings and any other special notes highlighted in the
manual. Improper installation of the furnace or failure to follow safety
warnings could result in serious injury, death, or property damage.
These instructions are primarily intended to assist qualified individuals
experienced in the proper installation of this appliance. Some local
codes require licensed installation/service personnel for this type of
equipment. Please read all instructions carefully before starting the
installation. Return these instructions to the customer's package for
future reference.
INSTALLER NAME:
CITY:
INSTALLATION ADDRESS:
CITY:
UNIT MODEL #
UNIT SERIAL #
Minimum clearances as showni n
Figure 1 (page
6)?
Has the owner's information been
reviewed with the home-owner?
Has the literature package been
left near the furnace?
PROPOSITION 65 WARNING:
WARNING: This product contains chemicals known to
the state of California to cause cancer.
WARNING: This product contains chemicals known to
the state of California to cause birth defects or other
reproductive harm.
Specifications & illustrations subject to change without notice or incurring obligations.
O' Fallon, MO | Printed in U.S.A. (06/13)

INSTALLATION / PERFORMANCE CHECK LIST

STATE:
STATE:
YES
NO
YES
NO
YES
NO
ELECTRICAL SYSTEM
Electrical connections tight?
Line voltage polarity correct?
Supply Voltage:
Has the thermostat been calibrated?
Is the thermostat level?
Is the heat anticipator setting correct?
GAS SYSTEM
Gas Type: (circle one)
Gas pipe connections leak tested?
Gas Line Pressure:
Installation Altitude:
Deration Percentage:
Furnace Input:
Supply Air Temperature:
Return Air Temperature:
Temperature Rise:
COMBUSTION AIR & VENTING SYSTEM
Is there adequate fresh air supply for
combustion and ventilation?
Vent free from restrictions?
Filter(s) secured in place?
Filter(s) clean?
Flue connections tight?
Is there proper draft?
YES
NO
YES
NO
VOLTS
YES
NO
YES
NO
YES
NO
Natural
Propane
Gas
YES
NO
(in - W.C.)
(FT.)
(%)
(Btuh)
(° F)
(° F)
(° F)
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO