Page of 12
Download Bookmark Comment

Nordyne Residential Gas Furnaces User's Information Manual

Nordyne user's information manual residential gas furnaces.
User's Information Manual
Residential Gas Furnaces
FOR YOUR SAFETY
!
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety precautions exactly could
result in serious injury, death or property damage.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your
building.
• Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
• If you cannot reach your gas
supplier, call the fire department.
• Extinguish any open flame.
— Installation and service must be
performed by a qualified installer,
service agency, or the gas supplier.
AVERTISSEMENT:
!
RISQUE D'INCENDIE OU
D'EXPLOSION
Le non-respect des consignes de sécurité pourrait
entraîner des blessures graves, la mort ou des
dommages matériels.
— Ne pas entreposer ni utiliser de
l'essence ni d'autres vapeurs ou
liquides inflammables dans le voisinage
de cet appareil, ni de tout autre appareil.
— QUE FAIRE S'UL Y A UNE ODEUR DE
GAZ
• Ne pas tenter d'allumer aucun appareil.
• Ne toucher à aucun interrupteur
électrique; n'utiliser aucun téléphone
dans le bâtiment.
• Appeler
immédiatement
fournisseur de gaz en employant le
téléphone d'un voisin. Respecter à
la lettre les instructions du
fournisseur de gaz.
• Si personne ne répond, appeler le
service des incendies.
— L'installation et l'entretien doivent être
effectués par un installateur qualifié,
un organisme de service ou le
fournisseur de gaz.
IMPORTANT
Read this owner information thoroughly
before attempting to operate or maintain this
furnace to become familiar with the
capabilities and use of your heating
appliance. Keep this with literature on other
appliances where you have easy access to it
in the future. If a problem occurs, check the
instructions and follow the recommendations
le
given. If the suggestions do not eliminate
your problem, call your NORDYNE Servicing
Contractor (Service PRO).
Any additions, changes, or conversions
required in order for the appliance to
satisfactorily meet the application needs
must be made by a qualified installer, service
agency, or the gas supplier using factory
specified and approved parts.

   Related Manuals for Nordyne Residential Gas Furnaces

   Summary of Contents for Nordyne Residential Gas Furnaces

  • Page 1

    If a problem occurs, check the instructions and follow the recommendations given. If the suggestions do not eliminate your problem, call your NORDYNE Servicing Contractor (Service PRO). Any additions, changes, or conversions required in order for the appliance to...

  • Page 3

    5 Pressure Switch 11 Burner Assembly 6 Control Board 12 Supply Air Limit 7 Blower Door Switch 13 Blower Assembly Figure 1. Furnace Parts Identified 1 Ignitor 2 Flame Sensor (Not Shown) 3 Gas Valve 4 Flame Roll-out Switch(s) 5 Pressure Switch...

  • Page 4

    4 Flame Roll-out Switch(s) 5 Pressure Switch 6 Vent Pressure Switch (93+ Only) 7 Control Board Figure 2. Furnace Parts Identified Downflow Condensing Furnace 8 Blower Door Switch 14 Condensate Drain 9 Vent Safety Switch 10 Low Voltage 15 In-Line Drain...

  • Page 5

    4 Secondary Gas Valve 5 Flame Roll-out Switch(s) 6 Pressure Switch 7 Vent Pressure Switch 8 Control Board 9 Blower Door Switch Figure 3. Furnace Parts Identified Downflow Furnace Models 10 Vent Safety Switch 16 In-Line Drain 11 Low Voltage Transformer...

  • Page 6

    1 Ignitor 2 Flame Sensor 3 Gas Valve 4 Flame Roll-out Switch(s) 5 Pressure Switch 6 Control Board Figure 4. Furnace Parts Identified Upflow/Horizontal Furnace 7 Blower Door 11 Supply Air Limit Switch 8 Vent Assembly 12 Blower Assembly 9 Low Voltage...

  • Page 7

    Do not use the furnace closet or area next to the furnace as a storage area. This area must be kept clear, clean, and free of lint. The furnace must also be kept clear of loose or exposed insulation materials.

  • Page 8

    In applications where the supply ducts carry heated air to areas outside the space in which the furnace is installed, the return air must be delivered to the furnace by duct(s) sealed to the furnace casing. These duct(s) must be full size and without interruption in the spaces outside of where the furnace is installed.

  • Page 9

    The filter(s) must be removed and cleaned monthly during the heating season to ensure proper furnace operation.

  • Page 10

    “N” the furnace has factory installed NOx reduction inserts. The inserts reduce the NOx emissions of the furnace. The NOx reduction inserts are located in the first pass of the top portion of the heat exchanger.

  • Page 11

    Figures 1, 2, 3 and 4). MANUFACTURER WARRANTY, OWNER RESPONSIBILITIES It is the sole responsibility of the homeowner to make certain the gas furnace has been correctly set up and adjusted to operate properly. The Manufacturer warrants the furnace to be free from defects in material or workmanship for the warranty period.

  • Page 12

    ¢708222y¤ 7082220 (Replaces 7081670) Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A. (01/03) 7082220...