Gas Supply & Piping; Leak Check - Nordyne TC Series User Manual

Two-stage condensing gas furnaces with fixed & variable speed blowers
Table of Contents

Advertisement

GAS SUPPLY & PIPING
WARNING:
FIRE OR EXPLOSION HAZARD
• Failure to follow safety warnings exactly
could result in serious injury or property
damage.
• Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
• Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
AVERTISSEMENT:
RISQUE D'INCENDIE OU D' EXPLOSION
• Le non-respect des avertissements de
sécurité pourrait entraîner des blessures
graves, la mort ou des dommages matériels.
• L'installation et l'entretien doivent être
effectués par un installateur qualifié, un
organisme de service ou le fournisseur
de gazstaller, service agency or the gas
supplier.
• Ne pas entreposer ni utiliser de l'essence ni
d'autres vapeurs ou liquides inflammables
dans le voisinage de cet appareil, ni de tout
autre appareil.
QUE FAIRE S'IL Y A UNE ODEUR DE GAZ
• Ne pas tenter d'allumer aucun appareil.
• Ne toucher à aucun interrupteur électrique;
n'utiliser aucun téléphone dans le bâtiment.
• Évacuer l'immeuble immédiatement.
• Appeler immédiatement le fournisseur de
gaz en employant le téléphone d'un voisin.
Respecter à la lettre les instructions du
fournisseur de gaz.
• Si personne ne répond, appeler le service
des incendies.
All gas piping must be installed in compliance with local
codes and utility regulations. In the absence of local codes
the gas line installation must comply with the latest edition
of the National Fuel Gas Code (ANSI Z223.1) or (CAN/
CGA B149.1 or .2) Installation Codes.
IMPORTANT NOTES:
• Some local regulations require the installation of a
manual main shut-off valve and ground joint union
external to the furnace. The shut-off valve should
be readily accessible for service and/or emergency
use. Consult the local utility or gas supplier for
additional requirements regarding placement of
the manual main gas shut-off. See
22).
• Gas piping must never run in or through air ducts,
chimneys, gas vents, or elevator shafts.
• Compounds used on threaded joints of gas piping
must be resistant to the actions of liquefied
petroleum gases.
• The main gas valve and main power disconnect to
the furnace must be properly labeled by the installer
in case emergency shutdown is required.
• Flexible gas connectors are not recommended for
this type of furnace but may be used if allowed by
local jurisdiction. Only new flexible connectors may
be used. Do not reuse old flexible gas connectors.
• A drip leg should be installed in the vertical pipe
run to the unit. See
Figure
Table 10 (page 36)
lists gas flow capacities for standard
pipe sizes as a function of length in typical applications
based on nominal pressure drop in the line.
The furnace may be installed for either left or right side gas
entry. When connecting the gas supply, provide clearance
between the gas supply line and the entry hole in the
furnace casing to avoid unwanted noise and/or damage to
the furnace. Typical gas hookups are shown in

Leak Check

AVERTISSEMENT:
RISQUE D'INDENDIE OU D'EXPLOSION
Le non-respect des avertissements de sécurité
pourrait d'entraîner des blessures graves, la
mort ou des dommages matériels.
Ne jamais utiliser une flamme nue por
vérifier la présence des fuites de gaz. Pour
la vérifi
de tous les joints, utiliser
plutôt une solution savonneuse commerciale
fabriquée spécifiquement pur la détection des
fuites de gaz. Un incendie ou une explosion
peut entraîner des dommages matériels, des
blessures ou la mort.
Figure 20 (page
20.
Figure
20.
21