Identify And Locate Components - Lincoln Electric IM795 Operator's Manual

For use with machine code numbers : 10982; 10983
Table of Contents

Advertisement

A-2
Read entire installation section before starting
installation.
SAFETY PRECAUTIONS
WARNING
ELECTRIC SHOCK can kill.
• Only qualified personnel should perform
this installation.
• Only personnel that have read and under-
stood the SP 170-I Operating Manual
should install and operate this equipment.
• Machine must be plugged into a receptacle
which is grounded per any national, local
or other applicable electrical codes.
• The SP 170-I power switch is to be in the
OFF ("O") position when installing work
cable and gun and when connecting power
cord to input power.
IDENTIFY AND LOCATE
COMPONENTS
If you have not already done so, unpack the SP 170-I
from its carton and remove all packing material
around the SP 170-I. Remove the following loose
items from the carton (see Figure A.1):
1. SP 170-I
2. Gun and cable assembly
3. Literature and miscellaneous including:
a) This operating manual
b) Contact tips:
SP 170-I
2
.025" (0.6mm) for solid wire
2
.030" (0.8mm) for solid wire
1
.035" (0.9mm) for cored wire
c) 5/64" (2.0 mm) Hex key wrench for removal of
drive roll.
4. 10 ft (3,0 m) work cable.
5. Work clamp.
6. 14.0 ft (4.3 m) .19" (4.8 mm) dia. gas hose
7. 2- Hose clamps
8. Gas nozzle
(1)
The gun is ready to feed .035" (0.9mm) diameter.
INSTALLATION
(1)
SP 170-I
1
E
3
8
5
FIGURE A.1
A-2
2
4
6
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp 170-i

Table of Contents