Termination Clearances - Vermont Castings INDVRCBSB Installation And Operating Instructions Manual

Intrepid direct vent gas heater
Table of Contents

Advertisement

Intrepid® Direct Vent - Rear Vent Gas Heater

TERMINATION CLEARANCES

Termination Clearances
Termination clearances for buildings with combustible and non-combustible exteriors.
Termination clearances for buildings with combustible and noncombustible exteriors.
Inside Corner
G
V
Balcony -
with no side wall
M =
Combustible &
Noncombustible
12" (305 mm)
*NOTE: Termination in an alcove space (spaces open only on one side
and with an overhang) is permitted with the dimensions specified for
vinyl or non-vinyl siding and soffits. 1. There must be a 3' (914 mm) min-
imum between termination caps. 2. All mechanical air intakes within 10'
Fig. 12 Termination clearances.
12
Outside Corner
G =
Combustible
6" (152 mm)
V
Noncombustible
2" (51 mm)
Balcony -
with perpendicular side wall
M
M
V
Combustible &
Noncombustible
M = 12" (305 mm)
P = 6" (152 mm)
F =
Combustible
6" (152 mm)
Noncombustible
2" (51 mm)
F
V
P
(1 m) of a termination cap must be a minimum of 3' (914 mm) below the
termination cap. 3. All gravity air intakes within 3' (914 mm) of a termina-
tion cap must be a minimum of 1' (305 mm) below the termination cap.
Alcove Applications*
D
C
C
V
E
O
E
= Min. 2" (51 mm) for
non-vinyl sidewalls
Min. 12" (305 mm) for
vinyl sidewalls
O
= 8' (2.4 m) Min.
No. of
Caps
D
.
C
min
max
1
3' (914 mm) 2 x D
actual
2
6' (1.8 m)
1 x D
actual
3
9' (2.7 m)
2/3 x D
4
12' (3.7 m) 1/2 x D
D
= Number of Termination caps x 3
Min.
C
= (2 / Number termination caps) x D
Max.
.
actual
actual
Actual