Connecting The Power Input Cable Assembly To Power Sources - Lincoln Electric LN-9 SVM127-A Service Manual

Wire feeder
Table of Contents

Advertisement

A-7
CONNECTING THE POWER INPUT
CABLE ASSEMBLY TO POWER
SOURCES
WARNING
Turn input supply power to the power source OFF
before connecting the LN-9 or LN-9F wire feeder.
Connect to an appropriate Lincoln power source as fol-
lows:
1. If using a multipurpose source (such as the DC-
250, DC-400 and DC-600), be sure it is properly
set for the welding process being used. See the
topic "Making a Test Weld," in the Operation
section of this manual.
For terminal strip connections using the K196 power
input cable, connect the input cable to the power
source exactly as specified on the appropriate LN-9
model connection diagram:
Figure A.5 for DC-250, DC-400 and CV-400, CV-500 l
Figure A.6 for DC-600
Figure A.7 for DC-1000
Figure A.8 for Pulse Power 500
INSTALLATION
Depending on the power source and process you are
using, the jumpers on the LN-9 voltage board may
have to be changed. As shipped, the LN-9 is connect-
ed for use with the DC-250 DC-400, CV-400, CV-500-I
and DC-600. For other power sources, refer to the
appropriate connection diagram.
NOTE: If you are using the Pulse Power 500 or DC650
Pro, the K442-1 Pulse Power Filter Kit must be
installed in the LN-9. See the instructions included with
the kit.