M A T E R I A L S A F E T Y D A T A S H E E T
Conforms to Hazard Communication Standard 29CFR 1910.1200 Rev. October 1988
Manufacturer/
The Lincoln Electric Company
Supplier:
22801 St. Clair Avenue
Cleveland, OH 44117-1199
(216) 481-8100
I M P O R T A N T !
This section covers the materials from which this product is manufactured. The fumes and gases produced during welding with the normal
use of this product are covered by Section V; see it for industrial hygiene information.
CAS Number shown is representative for the ingredients listed.
(1)
The term "hazardous" in "Hazardous Materials" should be interpreted as a term required and defined in the Hazards Communication
Standard and does not necessarily imply the existence of any hazard. All materials are listed on the TSCA inventory.
Ingredients:
Nickel based wire
Nominal wire composition:
Nickel*****
Chromium*****
Molybdenum
Niobium
Iron
Manganese*****
Supplemental Information:
is 10 milligrams per cubic meter. PEL value for iron oxide is 10 milligrams per
cubic meter. TLV value for iron oxide is 5 milligrams per cubic meter.
(*****)
Subject to the reporting requirements of Sections 311, 312, and 313 of
the Emergency Planning and Community Right-to-Know Act of 1986
and of 40CFR 370 and 372.
Non Flammable; Welding arc and sparks can ignite combustibles and flammable products. See Z49.1 referenced in Section VI.
Product is inert, no special handling or spill procedures required. Not regulated by DOT.
Rev 11/06b
Date:
Trade Name:
Sizes:
Supersedes:
For Welding Consumables and Related Products
SECTION I - IDENTIFICATION
SECTION II - HAZARDOUS MATERIAL (1)
(*) Not listed. Nuisance value maximum
SECTION III - HAZARD DATA
2/26/07
MSDS No.:
LNT/LNM/LNS NiCro 60/20
All
New
Product Type:
Nickel Based Solid Wire
AWS ERNiCrMo-3
Classification:
CAS No.
Wt.%
7440-02-0
> 58
7440-47-3
7439-98-7
7440-03-1
7439-89-6
7439-96-5
< 0.5
(b) The OSHA PEL for chromium (VI) is 5 micrograms
(0.005 milligrams) per cubic meter. The TLV for water
soluble chromium (VI) is 0.05 milligrams per cubic meter
and the TLV for insoluble chromium (VI) is 0.01
milligrams per cubic meter.
(c) Values are for manganese fume. STEL (Short Term
Exposure Limit) is 3.0 milligrams per cubic meter.
Values are those proposed by OSHA in 1989. Present
PEL is 5.0 milligrams per cubic meter (ceiling value).
(CONTINUED ON SIDE TWO)
US-W1460
TLV
PEL
3
mg/m
mg/m
100
10*
10*
1.5
1
22
0.5(b)
1.0(b)
9
10
10
3.5
10*
10*
< 5
10*
10*
0.2
1.0(c)
3

Advertisement

loading

Summary of Contents for Lincoln Electric Welder

  • Page 1 M A T E R I A L S A F E T Y D A T A S H E E T For Welding Consumables and Related Products Conforms to Hazard Communication Standard 29CFR 1910.1200 Rev. October 1988 Manufacturer/ The Lincoln Electric Company Supplier: 22801 St. Clair Avenue Cleveland, OH 44117-1199...
  • Page 2 At a minimum this includes welder's gloves and a protective face shield, and may include arm protectors, aprons, hats, shoulder protection, as well as dark substantial clothing. Train the welder not to permit electrically live parts or electrodes to contact skin . . . or clothing or gloves if they are wet. Insulate from work and ground.