Variable Flame Adjustment - Superior DRT35STDMN Installation And Operation Instructions Manual

Drt35 series see through and peninsula direct vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
Superior
DRT35 See Through and Peninsula Direct Vent Gas Fireplace
TM
Variable Flame Height Adjustment
Manifold Pressure Port
SIT Millivolt Gas Valve
Note: The piezo ignitor is located on the modesty panel - refer to Figure 1.
Figure 74
Honeywell Electronic
Figure 75
Millivolt Appliances -
To light millivolt appliances refer to the detailed
lighting instructions found on page 60 (English)
and page 61 (French). Millivolt appliance
lighting instructions may also be found on the
pull out lighting instruction labels attached to
the gas control valve.
Millivolt appliances are fitted with an ON/OFF
Rocker Switch for appliance ON/OFF control.
Refer to Figure 73 for its location. Once the
pilot is lighted, the ON/OFF rocker switch will
control the appliance ON/OFF operation. To
operate: Toggle the switch between its ON and
OFF positions.
48
Inlet Pressure Port
Main Gas
Control Knob
If your millivolt appliance is equipped with an
optional remote wall switch or remote control
kit and the pilot is lit, the appliance main burner
may be turned on and off with the wall switch
or remote control.
Electronic Appliances -
To light electronic appliances refer to the
detailed lighting instructions found in both
English and French on pages 62 and 63 of
these instructions respectively. Electronic
appliance lighting instructions may also be
Gas Valve
found on the pull out lighting instruction labels
attached to the gas control valve. Electronic
appliances are fitted with an ON/OFF Rocker
Switch for appliance ON/OFF control. Refer to
Figure 73 for its location.
Once the pilot is lighted, the ON/OFF rocker
switch will control the appliance ON/OFF opera-
tion. To operate: Toggle the switch between its
ON and OFF positions.
If your electronic appliance is equipped with an
optional remote wall switch or remote control
kit the appliance main burner may be turned on
and off with the wall switch or remote control.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Installation and Operation Instructions
900300-00, 02/2015
Variable Flame Height Adjustment
( Millivolt Appliances only)
1. All Millivolt appliances are equipped with
a variable gas control valve. Flame height for
these models may be adjusted through a range
between fixed low and high settings, alternately,
while the appliance is in operation.
Adjust the flame height as desired after lighting
the appliance by rotating the variable adjustment
control knob located on the front of the valve
(refer to Figure 74). (An extension is provided
to this knob so that the adjustment may be made
at the modesty panel.)
2. When lit for the first time, this appliance will
emit a slight odor for an hour or two. This is due
to the "burn-in" of internal paints and lubricants
used in the manufacturing process.
3. Keep lower control compartment clean by
vacuuming or brushing at least twice a year.
More frequent cleaning may be required due to
excessive lint from carpeting, bedding materials,
etc. It is important that control compartments,
burners and circulating air passageways of the
appliance be kept clean and clear of obstruction
of venting and combustion air.
4. Always turn off gas to the pilot (millivolt
appliances) before cleaning. Before re-lighting,
refer to the lighting instructions in this manual.
Instructions are also found on a pull-out panel
located on the floor of the appliance.
5. Always keep the appliance area clear and
free from combustible materials, gasoline and
other flammable liquids.
6. Remember, Millivolt appliances have a con-
tinuous burning pilot flame. Exercise caution
when using products with combustible vapors.