Muffler Outlet Pipe; Spark Arrester; High Frequency Generators For Tig Applications; Remote Control - Lincoln Electric COMMANDER 500 Operator's Manual

Lincoln electric welder user manual
Hide thumbs Also See for COMMANDER 500:
Table of Contents

Advertisement

A-5

MUFFLER OUTLET PIPE

Remove the plastic plug covering the muffler outlet
tube. Using the clamp provided secure the outlet pipe
to the outlet tube with the pipe positioned such that it
will direct the exhaust in the desired direction.

SPARK ARRESTER

Some federal, state or local laws may require that
gasoline or diesel engines be equipped with exhaust
spark arresters when they are operated in certain loca-
tions where unarrested sparks may present a fire haz-
ard. The standard muffler included with this welder
does not qualify as a spark arrester. When required by
local regulations, a suitable spark arrester, must be
installed and properly maintained.
CAUTION
An incorrect arrester may lead to damage to the engine
or adversely affect performance.
------------------------------------------------------------------------
HIGH FREQUENCY GENERATORS
FOR TIG APPLICATIONS
The K799 Hi-Freq Unit and the K930-1 or -2 TIG
Module are suitable for use with the Commander 500.
The Commander 500 is equipped with the required
R.F. bypass circuitry for the connection of high fre-
quency generating equipment.
bypass network supplied with the K799 Hi-Freq Unit
does NOT need to be installed into the Commander
500.
The Commander 500 and any high frequency generat-
ing equipment must be properly grounded. See the
K799 Hi-Freq Unit and the K930-1 or-2 TIG Module
operating manuals for complete instructions on instal-
lation, operation, and maintenance.
INSTALLATION

REMOTE CONTROL

OUTPUT
The Commander 500 is equipped with a 6-pin & 14-pin
connector. The 6-pin connector is for connecting the
K857 or K857-1 Remote Control (Optional) or in the
case of TIG welding applications, with the foot or hand
Amptrol (K870 or K963-1 respectively).
The 14-pin connector is used to directly connect a wire
feeder or TIG Module (K930-1 or -2) control cable.
NOTE: When using the 14-pin connector, if the wire
feeder has a built in power source output control, do
not connect anything to the 6-pin connector.

WELDING TERMINALS

The Commander is equipped with a toggle switch for
selecting "hot" welding terminals when in the "WELD
TERMINALS ON" position or "cold" welding terminals
when in the "REMOTELY CONTROLLED" position.
The high frequency
COMMANDER 500
A-5