D-3
EVERY DAY OR EVERY 8 HOURS
FIRST SERVICE-(20 / 50 HOURS)
EVERY 100 HOURS OR 3 MONTHS
EVERY 200 HOURS OR 6 MONTHS
EVERY 400 HOURS OR 12 MONTHS
EVERY 600 HOURS OR 18 MONTHS
I
I
I
R
R
R
R
C
C
R
I
I
C
C
R
I
I
I
I
I
I = Inspect
NOTES:
(1) Consult Engine Operators Manual for oil recommendations.
(2) Consult Engine Operators Manual for additional maintenance schedule information.
(3) Fill slowly! Ensure correct quantity is used.
Above operations to be carried out by trained personnel with reference to the workshop manual where necessary.
These preventive maintenance periods apply to average conditions of operation.
If necessary use shorter periods.
MAINTENANCE
FOR CODES 10658 AND BELOW
ENGINE SERVICE
ENGINE SERVICE (NOTE 2)
MAINTENANCE ITEM
Coolant level
Concentration of antifreeze
R
Coolant (NOTE 3)
Engine oil level (NOTE 1)
Engine oil (NOTE 1 & 3)
Engine oil filter
Drain water separator & fuel strainer
Fuel filter canister
Tension of alternator drive belt
Alternator drive belt wear
R
Alternator drive belt
Air filter (earlier check may be req'd.)
Air filter element
Check and adjust idle speed
I
Tighten cylinder head
I
Valve clearances
I
Electrical systems
All nuts and bolts for tightness
Injector performance
Leaks or engine damage
Battery
C = Clean
R = Replace
CLASSIC 300D
TYPE OR QUANTITY
50/50 Water/Ethylene Glycol
9.5qrts, (9.0L)
8.7qrts, (8.2L) (including filter)
Perkins #140517000
Perkins #1300366120
Perkins # 080109080
Donaldson #P181050 or Nelson #70206N
Intake .008", exhaust .008"
Contact Perkins
BCI Group 24
D-3
5/06
S20919-2