Enabling Functioning Of The External Temperature Probe By The Remote Control - Biasi Advance Plus 16S User Manual And Installation Instructions

Hide thumbs Also See for Advance Plus 16S:
Table of Contents

Advertisement

Fig. 7.9
• Open the gas cock
• Make sure that the ambient thermostat is
in the "heat request" position".
• Check the correct functioning of the boiler.
• Check the gas pressures and flow rates
as shown in section "GAS CONVER-
SION" to page 68 of this booklet.
• Check that the condensate produced dur-
ing functioning fills the pipe and is regu-
larly drained in the draining plant pipe.
• Switch off the boiler by pressing the
11 (Fig. 7.8) key for 2 seconds until the
symbol appears on the LCD dis-
play (Fig. 7.7).
The boiler will now go through an ignition
sequence and the burner will light.
If after four ignition attempts (about four
minutes) the boiler does not function and a
code that alternates between the letter Er
and the writing RESET appear on the LCD
display, it indicates that the safety lock-out
has stopped the boiler. The display back-
ground flashes (Fig. 7.10).
RESET
RESET
Fig. 7.10
- 56 -
COMMISSIONING
Press the reset key on the boiler control
panel 11 (Fig. 7.8) to reset its functioning.
°C
For the first lighting up and following main-
tenance procedures for the gas supply, it
may be necessary to repeat the resetting
operation several times so as to remove the
air present in the pipework.
After five consecutive resetting attempts the
reset button is inhibited. To restore its func-
tion it is necessary to switch the boiler off
and on from the electrical mains, using the
fused spur isolation switch fitted adjacent to
the appliance.
7.9
Functioning with the external probe in the
boiler must be enabled if the remote control
(optional) is used.
Act on the programming of the REMOTE
control to enable its functioning if the re-
mote control (optional) is used.
• Press button
Fig. 7.11
Press buttons
time to enter the transparent programming
(Fig. 7.12)
Enabling functioning of the
external temperature probe by
the remote control
for more than 3 seconds to
enter in
mode.
0
21
3
1
8
6
9
1 5
1
2
and
at the same