4

TROUBLESHOOTING

Fault/Error Identifi cation and Remedy
If you notice something abnormal while in use, immediately stop
using this product and shut off the gas valve.
In a case like this
(Symptom)
Things to check
(Cause)
Forgot to turn on the gas valve
or the gas valve is not
suffi ciently turned on.
Air is trapped inside the gas
pipe
Gas pressure is
not appropriate
Bent or squashed rubber hose
Not fully connected to
the fuse cock
Deterioration of rubber hose
due to wear and tear
Dirt on the electrode of ignition
system
Clogged fl ame hole or air hole
Improper installation of glass
Improper ignition operation
Lead wire connection problem
for ignition system
Failure of ignition system
Gas type on the nameplate and
gas type used are not matched
If the problem still persists even after you have checked the above items, stop using the griller
immediately and contact your dealer or any Rinnai offi ce.
WARNING
Low
High
- 12 -
Action to be taken
Check the position of the burner
control knob and then fully turn on
the gas valve.
Repeat ignition operation with care
until gas is properly supplied.
Request for inspection if this is also
observed on other appliances.
Straighten the bent hose in case of
rubber hose connection.
Fully connect the rubber hose to the
fuse cock in case of rubber hose
connection
Replace the rubber hose or cut off
the hose tip in case of rubber hose
connection.
Wipe off the dirt. If problem persists,
request for inspection.
Remove the clogging object.
If problem persists, request for
inspection.
Install the glass properly.
Refer to "How to Use (Ignition)"
Request for inspection.
Request for inspection, repair or
parts repair
Request for inspection or repair