Flow Limiter - Biasi RIVA ADVANCE HE M110.24SM/C Service Manual

Wall hung, fan flue, room sealed, high efficiency gas boiler
Hide thumbs Also See for RIVA ADVANCE HE M110.24SM/C:
Table of Contents

Advertisement

D.h.w. flow switch, filter and flow limiter
3
Unscrew the body 2(Fig. 14.3) and extract the
flow switch group.
4
To remove the filter from the flow switch group
separate the filter 9 from the threaded ring
(Fig. 14.3) by levering it.
5
Reassemble the parts following the removing se-
quence in reverse order.
14.6

Flow limiter

The M110.24SM/... model is factory fitted with a 10 litre/
min. flow limiter.
If on the M110.32SM/... model the flow rate of the d.h.w.
circuit is too high, it is possible to limit it by installing a
flow limiter. The following sizes are available:
30
Nominal flow rate (litres/min)
10
12
To install the threaded ring with the flow limiter:
1
Remove the flow switch group as explained in the
section 14.5.
2
Remove the filter from the flow switch group.
3
Unscrew the threaded ring 7 (Fig. 14.3) and re-
move it from the body 2.
4
Reassemble the group following the above se-
quence in reverse order.
Colour
Yellow
Brown

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Riva advance he m110.32sm/c

Table of Contents