Checks; Removal Of The Gas Valve - Biasi RIVA ADVANCE HE M110.24SM/C Service Manual

Wall hung, fan flue, room sealed, high efficiency gas boiler
Hide thumbs Also See for RIVA ADVANCE HE M110.24SM/C:
Table of Contents

Advertisement

E
F
Fig. 11.4
15
Keep pressed the reset button C for about 10
seconds (Fig. 11.4) until the lock ---out signal
lamp D blinks.
The lamps E should give the indication as in
16
Fig. 11.5.
Where:
Fig. 11.5
17
Release and keep the reset button C pressed for
more than 5 seconds until the lock ---out signal
lamp D is switched off.
The boiler will now go through an ignition se-
quence and the burner will light.
18
Open at least one hot water tap fully.
Adjusting minimum gas valve setting
19
Set the knob F to the minimum position as illus-
trated in Fig. 11.6
E
F
Fig. 11.6
20
Allow the analyser to give a stable reading.
21
Read the CO
% value.
2
It should be between 8,8 and 9,0 %.
To adjust the CO
2
by unscrewing it and rotate the plastic screw 1
(Fig. 11.2) (by rotating it clockwise the CO
creases).
Checking the maximum gas valve setting
22
Set the knob F to the maximum position as illus-
trated in Fig. 11.7
B
C
D
Lamp OFF
Lamp ON
B
C
D
% value remove the brass plug
E
Fig. 11.7
23
Allow the analyser to give a stable reading.
24
Read the CO
and 9,3 %.
25
Switch off the boiler and turn off the hot water
tap(s).
26
Close the air---flue sampling points.
27
After adjustment fit the protective brass plug (1,
Fig. 11.2).
Important: after the gas pressure checks and any
adjustment operations, all of the test points must be
sealed.
11.4

Checks

Warning: isolate the boiler from the mains
electricity
covering or component.
Check the on---off operators coils
n
1
Remove the front panel of the case.
2
Disconnect the electrical connector 3 (Fig. 11.2).
3
Measure the electrical resistance between the
connector pins of the on---off operators as illus-
trated in Fig. 11.8.
ON---OFF Operator
approx. 6 400 Ω*
ON---OFF Operator
approx. 920 Ω*
* at ambient temperature.
Fig. 11.8
11.5

Removal of the gas valve

Warning: isolate the boiler from the mains
electricity
% in-
covering or component.
2
1
Remove the front panel of the case as explained
in the section 2.3 of this manual.
2
Remove the screw G and disconnect the con-
nector H (Fig. 11.9).
F
B
C
% value. It should be between 8,3
2
supply
before
removing
supply
before
removing
Gas valve
D
any
any
25