MT VERNON-AE TROUBLE SHOOTING MANUAL
8:
THE FIREPOT THERMO-
COUPLE STARTS READING
THE TEMPERATURE RISE
AND THE UNIT WILL GO INTO
"SOFT-START LOW".
9:
SOFT-START LOW IS A
TIMED MODE AND WILL VARY
IN LENGTH DEPENDING ON
THE FUEL TABLE SELECTED.
10:
THE IGNITER WILL
SHUT OFF AFTER SOFT
START LOW EXPIRES.
11:
SOFT-START MEDIUM
WILL DISPLAY AFTER SOFT
START LOW HAS EXPIRED.
THE LENGTH OF THIS MODE
WILL VARY DEPENDING ON
THE FUEL SELECTED.
12:
THE DROP TUBE
THERMOCOUPLE WILL
BEGIN READING TEMPERA-
TURE. 105 DEGREES WILL
BE NEEDED TO TURN THE
CONVECTION BLOWER ON.
13:
AS THE TEMPERATURE
RISES, THE CONVECTION
BLOWER WILL INCREASE IN
SPEED.
4-24-08
OPERATION CHART
SOFT-START LOW TIMES:
SOFTWOOD......................4 MINUTES
HARDWOOD.....................4 MINUTES
UTILITY..............................4 MINUTES
CORN................................14 MINUTES
WHEAT..............................10 MINUTES
SUNFLOWER SEEDS.......4 MINUTES
SOFT-START MEDIUM TIMES:
SOFTWOOD......................5 MINUTES
HARDWOOD.....................5 MINUTES
UTILITY..............................5 MINUTES
CORN................................12 MINUTES
WHEAT..............................10 MINUTES
SUNFLOWER SEEDS.......5 MINUTES
PAGE 4
7020-057C