Quadra-Fire MT. VERNON AE Troubleshooting Manual page 5

Table of Contents

Advertisement

MT VERNON-AE TROUBLE SHOOTING MANUAL
14:
THE WALL CONTROL
WILL NOW DISPLAY THE HEAT
OUTPUT SETTING IN THE
MANUAL OR AUTO MODE.
AUTO: (L,ML,M,MH,H)
MAN: (L,ML,M,MH,H)
15:
ONCE THE THERMO-
STAT IS SATISFIED OR THE
BURN CYCLE HAS TIMED OUT
FOR AN AUTO-CLEAN CYCLE,
THE FEED MOTOR WILL SHUT
OFF.
16:
THE UNIT WILL GO INTO
"SHUTDOWN" MODE. THIS MODE
WILL LAST FOR 10 MINUTES.
THE DROP TUBE T-COUPLE WILL
ALSO COOL DOWN AND REDUCE
THE SPEED OF THE CONVEC-
TION BLOWER.
17:
THE UNIT WILL DISPLAY
"AUTOCLEAN" IN THE UPPER
LEFT HAND CORNER.
18:
THE THERMOCOUPLE
HAS TO READ 550 DEGREES
OR LESS BEFORE THE AUTO-
CLEAN CYCLE BEGINS.
19:
AFTER THE AUTO-
CLEAN IS COMPLETE, THE
EXHAUST BLOWER WILL RUN
FOR 20 MINS AND SHUT OFF.
UNIT IS READY TO START
ANOTHER BURN CYCLE.
4-24-08
OPERATION CHART
PAGE 5
7020-057C