INSTALLATION SECTION – Page 7

INSTALLATION INSTRUCTIONS

The installation of the boiler must be in accordance with the relevant requirements of the Gas Safety Regulations,
Building Regulations, lEE Regulations and the byelaws of the local Water Undertaking.
It should be in accordance also with any relevant require-ments of the local gas region and local authority and the
relevant recommendations of the following British Standard Codes of Practice:
CP 331
Installation of pipes and meters for town gas.
Part 3 Low pressure installation pipes.
BS 5376
Selection and installation of gas space heating (1st and 2nd family gases)
Part 2 Boilers of rated input not exceeding 60kW.
BS 5449
Central heating for domestic premises
Part 1 Forced circulation hot water systems
CP 342
Centralized hot water supply
Part 1 Individual dwellings
Part 2 Buildings other than individual dwellings.
BS 5440
Flues and air supply for gas appliances of rated input not exceeding 60kW (1st and 2nd family
gases)
Part 1 Flues
Part 2 Air supply.

1. UNPACKING

a. The appliance will arrive on-site packed in two cartons as follows:
Carton No. 1
The casing
The air duct
The balanced flue terminal
Controls cover
Accessory screw pack A, B, D, E, F and G
Flue hood attaching parts
Flue hood
Literature
The boiler backplate
Carton No. 2
The boiler assembly and the gas cock.
b. Open Carton No. 1. There is no need to open the boiler carton at this stage.

2. FITTING THE AIR DUCT TO THE WALL-

See
Figure 4
a. Decide on the most suitable position for the boiler, taking into account the information given previously, paying
particular attention to the siting of the balanced flue terminal on the outside wall of the building. It is a good idea to
offer the air duct up to the wall and draw a pencil mark around the duct where it will go through the wall.
2.7 bar (9Oft/wg.)
RC ½ (½in. B.S.P.) loose
key
3 - way terminal block on
control panel
½in. B.S.P. Honeywell
Com-
pact V4, 600A 1023
Ranco C26
Furigas
Honeywell Q314A
Vernitron with Buccleugh
Electrode
RS50S
Max. Working Head:
Main Gas Cock:
Electrical Connections:
Combination Gas
Control:
Thermostat:
Main Burner:
Pilot Burner:
Pilot Ignitor:
2.7 bar (9Oft/wg.)
RC ½ (½in. B.S.P.) Loose
key
3 - way terminal block on
control panel
½in. B.S.P. Honeywell
Com-
pact V4, 600A 1023
Ranco C26
Furigas
Honeywell Q314A
Vernitron with Buccleugh
Electrode