Gas Valve - Baxi Bermuda 45/4 M Installation And Servicing Instructions

Hide thumbs Also See for Bermuda 45/4 M:
Table of Contents

Advertisement

CHANGING COMPONENTS - Page 30

Gas Valve

ELECTRONIC CONTROL MODELS
Remove the screw holding the valve cover to the controls
mounting bracket and remove the cover.
Disconnect the electrical connections from the valve, noting
the position of each wire.
Remove the two screws holding the valve to the controls
mounting bracket adjacent to the union nut and tailpiece.
Undo the pilot feed pipe nut from the valve.
Remove the three screws holding the burner feed pipe to the
valve, being careful not to lose or damage the "O" ring seal.
Remove the valve from the controls mounting bracket.
Remove the tailpiece and union nut from the original valve
and fit to the new one.
Reassemble in reverse order.