INSTALLATION - Page 18
For installations requiring a permanent live ie:-
where the firefront is equipped with either lighting
effects or lighting effects and electronic ignition
proceed as follows:-
Connect the inlet supply cable(s) as indicated:-
Permanent live to L
Controls system switched live to SL
Control system neutral to N
Earth to
The circular part of the ring terminal on the earth wire must
be detached.
Remove the side cable clamp and connect the wire from the
fire front kit as indicated:-
Brown (live) to L
Blue (neutral) to N
Green and yellow (earth) to
Re-fit both cable clamps ensuring that the outer insulation is
securely held and re-fit the socket cover.
For installations not requiring a permanent live
ie: radiant fire fronts proceed as follows:-
Connect the inlet supply cable as indicated:-
Control system switched live to SL
Control system neutral to N
Earth to
Using the wire provided in the kit, link SL to L.
Re-fit the cable clamp ensuring that the outer insulation is
securely held and refit the socket Cover.
Ensure that all cables are routed away from the
boiler casing and hood.