INSTALLATION - Page 19
MANUAL CONTROL MODELS
NOTE: The cover must be replaced after making
electrical connections.
Undo the screw retaining the socket cover and plug and
socket to their mounting bracket.
Disconnect the input socket from the controls plug. Remove
the socket cover and inlet cable clamp.
For installations requiring a permanent live i.e. where the fire
front is equipped with either lighting effects or lighting effects
and electronic ignition, proceed as follows:-
Connect the inlet supply cable(s) as indicated:-
Permanent live to L2
Control system switched live to L1
Control system neutral to N
Route the earth through the cut out in the side of the socket
housing leaving sufficient length to connect the wire to the
earth terminal on the mounting bracket.
Remove the side cable clamp and connect the wire from the
firefront kit as indicated:
Brown (live) to L2
Blue (neutral) to N
Green &Yellow (earth) in a similar
manner to the mains earth wire.
Refit both cable clamps ensuring that the outer
insulation is securely held and refit the socket cover.
For installations where no permanent live is required i.e.
radiant firefronts, proceed as follows:
Connect the inlet supply cable as indicated:
Controls system switched live to L1
Control system neutral to N
Route the earth through the cut out in the side of the socket
housing leaving sufficient length to
connect the wire to the earth terminal on the mounting
bracket.
Refit the cable clamp ensuring that the outer insulation is
securely held and refit the socket cover.
Ensure that all cables are routed away from the boiler
casing and hood.