INSTALLATION - Page 21
MANUAL CONTROL MODELS
Replace the combustion box door and secure with the
screws previously removed.
Ensure that the sensing pipe locates over the pilot
breather sealing washer. The screws must be tight to
achieve the required seal and to ensure correct
operation of the Atmospheric Sensing Device.
Insert the thermostat phial through the rubber seal in the
door into the heat exchanger thermostat pocket. Engage the
capillary in the routing clips.
Connect the input socket to the valve plug and locate the
socket in the mounting bracket slot. Refit the socket cover
using the screw previously removed.
Refit controls heat shield. If a radiant appliance is to be
installed the heat shield from the fire kit can now be fitted.