Baxi Bermuda 45/4 M Installation And Servicing Instructions page 17

Hide thumbs Also See for Bermuda 45/4 M:
Table of Contents

Advertisement

INSTALLATION - Page 17
Electrical Connection
The appliance requires an electrical supply from the heating
controls system. A permanent live is required for firefronts
which have electronic ignition and/or light effects.
WARNING
The appliance must be earthed. The input cable for the
appliance must be not less than 0.75mm
227 (heat resistant). The system external
controls and the appliance must be supplied by the same
isolator. NOTE: The polarity of the electrical supply must
be correct otherwise the appliance will not operate.
OVERHEAT THERMOSTAT
Where an overheat thermostat modification kit is required,
the wiring instructions supplied in the kit must be followed.
Making the Electrical Connection
On installations where the firefront requires a permanent live
locate the kit in the firefront carton and extract the electrical
lead and plug assembly.
ELECTRONIC CONTROLS MODELS
Remove the electrical inlet socket from the PCB at
the rear left hand side of the control box.
Remove the socket cover and inlet cable clamp.
2
to IEC 53 Code
1
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bermuda 45/4 eBermuda 57/4 mBermuda 57/4 e

Table of Contents