Heat & Glo SL-550TR-E Owner's Manual page 33

Hide thumbs Also See for SL-550TR-E:
Table of Contents

Advertisement

Note: Use DVP Series
components only.
Figure 7.14
Note: Use DVP Series
components only.
INSTALLED
HORIZONTALLY
H
3
Figure 7.15
Rear Vent - Horizontal Termination
Venting with two 90º elbows
H
MAX.
V
MIN.
1
1
1-1/2 ft. 457 mm
Back to back elbows
3 ft.
914 mm
1 ft.
5 ft.
1.5 m
3 ft.
7 ft.
2.1 m
5 ft.
H
H
+ H
1
V
+ H
1
H
2
1-1/2 ft.
3-1/2 ft.
5-1/2 ft.
7-1/2 ft.
H
2
Heat & Glo • SL-550 / 750 / 950TR-E • 2118-900 Rev. AC • 3/15
H
MAX.
2
1 ft.
305 mm
305 mm
3 ft.
914 mm
914 mm
5 ft.
1.5 m
1.5 m
7 ft.
2.1 m
MAX. = 7 ft. (2.1 m)
1
MAX. = 14 ft. (4.3 m)
2
+ H
MAX. = 40 ft. (12.2 m)
1
2
V
1
H
Rear Vent - Horizontal Termination
Venting with three 90º elbows
H
MAX.
V
MIN.
1
1
457 mm
Back to back elbows
1.1 m
1 ft.
305 mm
1.7 m
2 ft.
610 mm
2.3 m
3 ft.
914 mm
H
MAX. = 7-1/2 ft. (2.3 m)
1
H
+ H
+ H
1
2
V
+ H
+ H
1
1
2
V
1
H
H
+ H
MAX.
1
2
2-1/2 ft.
762 mm
6 ft.
1.8 m
10 ft.
3.0 m
14 ft.
4.3 m
1
H
+ H
MAX.
2
3
1 ft.
305 mm
2 ft.
610 mm
4 ft.
1.2 m
6 ft.
1.8 m
13-1/2 ft.
MAX. = 13-1/2 ft. (4.1 m)
3
+ H
MAX. = 40 ft. (12.2 m)
3
1
H
+ H
+ H
MAX.
1
2
3
2-1/2 ft.
762 mm
5-1/2 ft.
1.7 m
9-1/2ft.
2.9 m
4.1 m
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents