2.4.
MDB settings
...
2.4.1
Recharge enabled
No
the vending machine will only deduct the cost from MDB
cards.
2.4.2.
Max CardRecharge
10.00
By setting MAX RECHARGE = 20.00, the credit on the
vending machine will be transferred to the card if the sum
does not exceed 20.00.
2.4.3.
Max card charge
10.00
25.00, the vending machine will reject all cards with a
credit which exceeds this amount. If this card is detected,
the display will not show the credit but a " ——" message
will be displayed and no sale will be carried out.
2.4.4.
Coins enabling
...
2.4.4.1.
Moneta
1/16
No
a particular coin. Coins beneath the vending machine scale
factor are always disabled and display the "N" setting.
2.4.5.
Alt. payout
No
the change-giver is called on to dispense change.
Change is limited to 255 times the scaling factor (typically
Euro12.75 for the Euro area - with scaling factor of 5). By
setting "No" change is given by exploiting the machine's
algorithm. Max. change is 60000 units (typically Euro 600
for the Euro area).
2.4.6.
Max change
0.00
MDB settings
Enables access to particular
f u n c t i o n s o f t h e M D B
protocol.
RECHARGE: Allows disabling
or enabling of any Saeco card
recharge operation.
By setting RECHARGE = NO
M A X CA R D R ECH A R G E :
Enables setting of the maximum
credit level, beyond which
all recharge operations (if
enabled) are ineffective.
MAX CARD VALUE: Enables
setting of the maximum credit
level, beyond which the card is
rejected by the system.
By setting Max card value =
COINS ENABLING: Enables
selection of which coins will
be accepted by the change-
giving coiner. By setting "Y" a
specific coin will be accepted.
On the contrary, the "N"
setting prevents the change-
giving coiner from accepting
ALT. PAYOUT: It enables/
disables use of Alternative
Payout for the level 3 MDB
change-giver. By setting "Yes"
MAX CHANGE: Enables setting
of the maximum amount of
change which can be dispensed
by the change-giving coiner.
Default = 10.00.
2.4.7.
Exact change
0
Key:
L
= channel with the lowest coin value below the minimum
level
M = channel with the medium-low coin value below the
minimum level
HL = channel with the medium-high coin value below the
minimum level
HH = channel with the highest coin value below the minimum
level
No.
Description
0
L or M or HL or HH
1
L or M
2
HL or HH
3
L or HH
4
L
5
M
6
HL
7
L and HH
8
HL and HH
9
L and M
10
L and M and HL and HH
11
L and HL or L and HH
12
L or HL and HH
13
HH
14
L and M and HL
15
Never (change always available)
Note
Even if the no change available message is displayed, the
vending machine continues to give change as long as coins
are present in the channels. The minimum level (same for all
channels) can be set on a special menu item.
2.4.8.
Min tube level
0
2.4.9.
Tube filling
...
2.4.10.
Tube emptying
...
English
EXACT CHANGE POLICY: In
MDB change-giving coiners,
the condition of no change
available can be selected
within the following table:
C H A N N E L L E V E L L O W :
Enables setting of the minimum
number of coins in the channels.
Default = 4.
MANUAL CHANNEL LOAD:
Allows the change-giving
coiner channels to be filled
manually. Press Esc to exit the
channel loading mode.
MANUAL CHANNEL EMPT.:
Allows the change-giving
coiner channels to be emptied
by pressing the beverage
selection keys.
35