1.4.
Boiler 1 temp.
00
2 boilers. The following table matches the boilers with the
vending machine models.
Model
Boiler 1
Espresso
Beverage and coffee boiler Not present
Instant
Beverage boiler
T.T.T.
Beverage and coffee boiler Not present
Cappuccino Beverage and coffee boiler Steam boiler
This menu option allows setting the operating temperature
of boiler 1.
1.4.1.
Temperatura min.
00
vending machine after a beverage has been dispensed.
The set value is expressed in centigrade.
1.4.2.
Temperatura max.
000
after a certain time from the last dispensing, in order to
compensate for the natural decrease of the temperature of the
hydraulic circuits. The set value is expressed in centigrade.
1.5.
Boiler 2 temp.
000
This setting is not used for the boiler of the Instant version
and in case the boiler 2 is not installed.
1.6.
Energy Save
machine. It is possible to select one or both modes.
1.6.1.
Stand-by Timeout
set by means of this menu option. By setting it to zero the
function is disabled.
When the stand-by mode is activated the boilers are turned
off and the display shows the message "Stand-by".
To exit the stand-by mode, press any button or insert some
credit. When normal operation is restored, the boilers are
turned on and the vending machine starts the warm-up
phase.
30
Boiler 1 temperature
According to the model, the
Phedra vending machine
may be equipped with 1 or
Boiler 2
Beverage boiler
MIN. TEMPERATURE
E n a b l e s s e t t i n g o f t h e
temperature to be maintained
for a few minutes by the
MAX. TEMPERATURE
E n a b l e s s e t t i n g o f t h e
temperature to which the
vending machine is brought
Boiler 2 temperature
This menu allows setting the
operating temperature for
boiler 2.
Energy Save
The "Stand-by" and "ECO"
modes allow reducing the
energy consumption of the
STAND-BY TIMEOUT
The "Stand-by" mode is
activated after some minutes
of inactivity which can be
1.6.2.
Eco Timeout
of this menu option. By setting it to zero the function is
disabled.
When the "ECO" mode is activated, the target temperature
of boiler 2 (steam boiler for the "Cappuccino" version and
auxiliary boiler for the "Instant" version) is reduced by a
preset value (see the following menu option).
The vending machine remains in its "Ready" status and no
message is shown to the user.
To exit the ECO mode, press any button or insert some credit.
When ECO mode is deactivated, the target temperature for
boiler 2 is restored and the machine starts the warm-up
phase.
1.6.3.
Delta Temp. Eco
1.7.
PreHeat
brew group, the brewing circuits for instant products or the steam
dispensing circuit.
1.7.1.
Coffee preheat.
00
This menu allows setting the seconds of inactivity after which
the pre-heating cycle has to take place. The settable values
are:
-
0 (zero) pre-heating cycle disabled,
-
from 60 seconds to 900 seconds at intervals of 60.
The default value is 300.
1.7.2.
InstProd preheat.
00
By enabling this function, the vending machine performs
a preliminary dispensing of water through the circuit
corresponding to the instant product selected. The user can
choose for which instant product prerinsing can be enabled,
by setting cu cm of water to be used.
INST.PROD.PREHEAT.
Example: the settings shown in the figure enable preheating
for instant product 1 with 10 units of water and do not enable
preheating for instant product 2.
ECO TIMEOUT
The "ECO" mode is activated
after some minutes of inactivity
which can be set by means
DELTA TEMP. ECO
It allows setting the °C reduction
to be applied to the temperature
of boiler 2 in "ECO" mode.
Preheating
This menu allows setting the
parameters related to the the
preheating operations for the
COFFEE PRE-HEATING
It allows enabling a pre-heating
cycle of the Brew Group if it
remains inactive for a period
of time.
PREHEAT. SOLUBLES
Enables selection of the
instant products for which the
preheating function will be
enabled.
INSTANT PRODUCT 01
10
INSTANT PRODUCT 02
0