SHADOW LOOP Activation prevents the gate from opening or closing so the gate won't hit a
INSIDE/OUTSIDE INTERRUPT LOOP DETECTOR (TB16)
INSIDE
INTERRUPT LOOP with SLIDE "OFF" and ATG "ON"
INSIDE
INTERRUPT LOOP with SLIDE "OFF" and ATG "OFF"
INSIDE
INTERRUPT LOOP with SLIDE "ON" and ATG "ON"
INSIDE
INTERRUPT LOOP with SLIDE "ON" and ATG "OFF"
OUTSIDE
INTERRUPT LOOP with ATG "OFF"
OUTSIDE
INTERRUPT LOOP with ATG "ON"
INTERRUPT BAR INPUTS (TB11)
INTERRUPT BAR Activation fully opens a closing gate and stops an opening gate. If RETRY is
Rev C
vehicle. If the gate is already moving, or if the gate is not fully opened or
closed, this input has no effect (swing gate only).
Gate fully open or closed: activation prevents the gate from moving. When
the Interrupt loop clears, the gate begins closing.
Gate opening or closing: activation halts the gate. When the Interrupt
Loop clears, an opening gate closes and a closing gate resumes its course.
Gate fully open or closed: activation prevents the gate from moving.
Gate opening or closing: activation halts the gate. When the Interrupt
Loop clears, the gate resumes its course.
Gate fully open or closed: activation prevents the gate from closing. When
the Interrupt loop clears, the gate begins closing.
Gate opening or closing: activation halts a closing gate. When the
Interrupt Loop clears, an opening gate closes and a closing gate resumes its
course.
Gate fully open or closed: activation prevents the gate from closing only.
Gate opening or closing: activation fully opens a closing gate and starts
the Reclose Timer if timer is "ON".
Gate fully open or closed: activation prevents the gate from closing only.
Gate opening or closing: activation fully opens the closing gate and starts
the Reclose Timer if timer is "ON".
Gate fully open or closed: activation prevents the gate from closing only.
Gate opening or closing: activation prevents the gate from closing. When
the interrupt loop clears, the gate begins closing.
ON, the gate waits 30 seconds, then tries to resume. The gate will re-try
twice before faulting out. If the Interrupt Bar remains active for more than 30
seconds, the gate will not retry.