Chamberlain BG 3000-B1 Installation And Operation Instructions Manual page 30

Barrier gate operator
Table of Contents

Advertisement

3. IF MAX RUN TIME LED IS TURNED ON ONLY
1. Limit cams do not engage the limit switches.
2. Broken belt.
3. The belt slips during gate movement.
4. Limit switch cable is disconnected.
5. Bad limit switch.
6. Stalled motor.
4. IF OPEN MTR LED IS TURNED ON ONLY
1. The motor thermal overload switch is popped.
2. The wires connecting the motor to the Control Board are disconnected
3. Bad motor.
5. IF FAULT LED IS TURNED ON ONLY
1. A limit switch is stuck closed.
2. The belt was broken before the start of the gate movement.
3. Interrupt Bar switch is activated.
4. Stalled motor at open or close limit.
Rev C
Doc 6001287 (01-20284)
25 of 40