SPANS AMERICA INSTALLATION AND SERVICE INFORMATION ADDRESS ORDER TO: ARE AVAILABLE 6 DAYS A WEEK THE CHAMBERLAIN GROUP, INC. CALL OUR TOLL FREE NUMBER - 1-800-528-6563 Electronic Parts & Service Dept. HOURS 7:00 TO 3:30 p.m. (Mountain Std. Time) 2301 N. Forbes Blvd., Suite 104...
Page 3
ASSEMBLE TRACK AND OPERATOR CAUTION WARNING KEEP DOOR BALANCED. STICKING OR BINDING DO NOT CONNECT ELECTRIC POWER UNTIL DOORS MUST BE REPAIRED. DOORS, DOOR INSTRUCTED TO DO SO. SPRINGS, CABLES, PULLEYS, BRACKETS AND THEIR HARDWARE MAY BE UNDER EXTREME TENSION AND CAN CAUSE SERIOUS PERSONAL 12/6/91 - 4/27/92 INJURY OR DEATH.
Page 4
INSTALL OPERATOR CAUTION: AT LEAST TWO PERSONS AND A STRONG, SAFE WORKING PLATFORM ARE REQUIRED FOR THE INSTALLATION OF OPERATOR. CAUTION TO AVOID DAMAGE TO DOOR AND OPERATOR, FIGURE 2 MAKE ALL DOOR LOCKS INOPERATIVE. SECURE LOCK(S) IN "OPEN" POSITION. Building Support IF THE DOOR LOCK NEEDS TO REMAIN...
Page 5
9. Raise operator straight up until the door can be COIL CORD (OPTIONAL) raised to the full open position. See Figure 5. REFER TO (A) IN ILLUSTRATION Temporarily secure to ceiling or rafters with rope Connect operator end of coil cord to junction box (not or other suitable means.
Page 6
CONNECT OPERATOR TO POWER SUPPLY AND INSTALL CONTROL STATION WARNING WARNING DISCONNECT POWER AT THE FUSE BOX BEFORE INSTALL THE CONTROL STATION WHERE THE PROCEEDING. DOOR IS VISIBLE, BUT AWAY FROM THE DOOR AND ITS HARDWARE. IF CONTROL STATION CANNOT BE OPERATOR MUST BE PROPERLY GROUNDED AND INSTALLED WHERE DOOR IS VISIBLE, OR IF ANY CONNECTED IN ACCORDANCE WITH LOCAL...
Page 7
WARNING TO AVOID SERIOUS PERSONAL INJURY OR DEATH FROM ELECTROCUTION, DISCONNECT ELECTRIC POWER BEFORE PROCEEDING WITH THE FOLLOWING ADJUSTMENTS. ADJUST LIMITS MAKE SURE LIMIT NUTS ARE POSITIONED BETWEEN LIMIT SWITCH ACTUATORS BEFORE PROCEEDING WITH ADJUSTMENT. Travel Nut Retainer 1. Depress open limit switch. The operator should stop.
EMERGENCY DISCONNECT SYSTEM WARNING DOOR ARM IS RELEASED FROM TROLLEY WHEN Header EMERGENCY DISCONNECT OPENS. Trolley Bracket TO AVOID BEING STRUCK BY DOOR ARM, DO NOT Track STAND UNDER THE ROPE OR DOOR ARM WHEN PULLING THE EMERGENCY RELEASE. Clevis Emergency TO DISCONNECT Chain...
Page 10
SINGLE PHASE WIRING DIAGRAM (For P.C. Board #14D0379) Brown SENSING AUXILARY LIMIT DEVICE LIMIT SWITCH SWITCH Brown CLOSE OPEN LIMIT LIMIT SWITCH SWITCH Yellow Yellow Gray Brown Brown Blue Brown Orange Brown Org. Blue Orange White White Blue Orange 14 T3 T2 T1 14 T3 T2 T1 Blue...
Page 11
SINGLE PHASE SCHEMATIC DIAGRAM (For P.C. Board #14D0379) Neutral 115v 1Ø Hot 115v 1Ø The Chamberlain Group, Inc. 1Ø Schematic GT Page 10 - 114A1540 10/8/92 White Black Single Phase Overload Protector Orange Black 115 Vac Only Orange P1-4 P1-1...
Page 12
THREE PHASE WIRING DIAGRAM (For PC Board #14D0379) Brown SENSING AUXILARY LIMIT DEVICE LIMIT SWITCH SWITCH Brown Brown Brown Orange CLOSE OPEN LIMIT LIMIT SWITCH SWITCH Yellow Yellow Gray Blue Brown Brown Orange Brown Blue Orange Blue Orange Orange 3/4 to 2HP White White ThreePhase...
Page 13
THREE PHASE SCHEMATIC DIAGRAM (For P.C. Board #14D0379) Hot 3Ø Hot 3Ø Hot 3Ø The Chamberlain Group, Inc. 3Ø Schematic White Orange Page 13 - GT Manual #114A1540 10/9/92 Three Phase Overload Relay (3/4 HP to 2 HP Only) Orange...
Page 14
WIRING KITS TYPE STATION B2, C2, D1, E2, T D1, E2 3 Button Function: Momentary contact to open, close and stop, plus wiring for sensing device to reverse and auxiliary devices to open and close with open override. B2, T, B2, C2, E2 T, TS B2, C2,...
Page 15
NEMA MOTOR WIRING DIAGRAMS he Chamberlain Group, Inc. NEMA Motor Wiring Diagrams NEMA MOTOR WIRING DIAGRAMS /1/92 SINGLE VOLTAGE 1 PHASE 1/3 & 1/2 H.P. 115 V only 115V 115V 230V Motor Motor Motor T2 White Black T1 - Blue...