Viper 60s Theory Of Operation And Maintenance Manual page 126

1/3-inch streaming cartridge tape dribe
Table of Contents

Advertisement

VIPER SCSI 60. 125
&
150 THEORY OF OPERA TlON AND MAINTENANCE
5.24.3 Completion Status
i
COMPLETION
I
I
. .
!
CODE
MESSAG~_~ DESC~IPTION
_ _ _ _
-J
OOh
02h
Good Status
• The media position is not changed
• The Viper is ready to accept appropriate command
• The drive remains in any previously set mode
• If a PREVENT command was issued, the LED is
always on and the Unit Attention Condition is set
upon media removal
• If an ALLOW command was sent, the LED goes
out at BOT. This allows media removal at BOT
without setting Unit Attention Condition
Check Condition
Extended Sense byte 02
IcODEIMESSA~E
I DESCRIPTION
04h
Hardware Error· Parity error either on SCSI
bus or the Viper drive
OSh
Illegal Request • The CDB contained an
invalid bit
06h
Unit Attention
• The cartridge was
changed prior to issuing
the PREVENT/ALLOW
command
5-68
• Viper drive has received a
Reset prior to the
PREVENT/ALLOW
command

Advertisement