Viper 60s Theory Of Operation And Maintenance Manual page 124

1/3-inch streaming cartridge tape dribe
Table of Contents

Advertisement

VIPER SCSI 60,
125
&
150 THEORY OF OPERA T/ON AND MAINTENANCE
5.23.3 Completion Status
COMPLETION
CODE
OOh
Good Status
DESCRIPTION
• The position of the Media is not changed
• Viper drive is ready to accept any appropriate
command
• Viper drive remains in any previously set mode
r - - - - - - - - - - - - - - - - - -
------~
...... - - -.....
~
02h
Check Condition
Extended Sense byte 02
rc?DE,
!"1ESS~GE
I
DESCRrPTIO~-~=_
02h
Not Ready
• A cartridge is not installed
in the drive
04h
Hardware Error • Parity error on either the
SCSI Bus orthe Viper drive:
the diagnostic failed
OSh
Illegal Request • The COB contains an
invalid bit
06h
Unit Attention
• The cartridge was changed
prior to accepting this
command
• The Viper drive was Reset
prior to accepting this
command
NOTE:
The LED signals three long, three short, and three long flashes. This sequence
repeats until the condition is cleared.
5-66