C. Venting & Use of Elbows
O
+
= Positive static pressure
O
-
= Negative static pressure
Figure 4.11
Harman pellet stoves depend on a combustion fan to pull air
through the unit for combustion. The venting system restricts
the ability of the combustion fan to move the required amount
of air through the unit. A system with too much resistance
will result in incomplete combustion, more frequent required
cleaning and poor unit performance. It is always best to
choose a location for the appliance that will result in a venting
system with the shortest equivalent vent length (EVL).
It is best to have your venting system designed by a Harman
authorized dealer before you finalize your purchase of an
appliance.
Equivalent Vent length: The equivalent vent length for
common pellet vent components are:
• 90° Elbows or Tee: 5 EVL Units
• 45° elbow: 3 EVL Units
• Vertical Pipe or Liner: ½ EVL Unit
• Horizontal Pipe or liner: 1 EVL Unit
The total allowable equivalent vent length is:
• 20 EVL for 3" pellet vent pipe or liner
• 30 EVL for 4" pellet vent pipe or liner
Due to the potential for fly ash accumulation in horizontal
venting sections, the maximum permissible horizontal venting
length is:
• 4 ft. for 3" & 4" pellet vent pipe.
16
+
+
Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15
Example: First Floor Installation
A unit is to be installed using 3" Pellet Pipe with 3 feet
of horizontal pipe, a Tee, 10 feet of vertical pipe, a 90°
elbow and a termination cap.
The equivalent vent length is:
3 ft. of Horizontal Pipe (1 x 3 EVL)
90° Elbow or Tee (1 x EVL)
10 ft. of Vertical Pipe (10 x .5 EVL)
90° Elbow or Tee (1 x EVL)
Termination Cap
Equivalent Vent Length
In the example system detailed above, the EVL was
138which is less than the maximum of 20 EVL for 3" pellet
vent pipe, thus this is a satisfactory venting configuration.
Example: Connection to Masonry Chimney
A unit is to be installed using 3" Pellet Pipe with 2 feet of
horizontal pipe, a Tee, 4 feet of vertical pipe, an elbow, a
Tee, 21 feet of vertical liner, and a termination cap.
The equivalent vent length is:
2 ft. of Horizontal Pipe (1 x 2 EVL)
90° Tee (1 x 5 EVL)
4 ft. of Vertical Pipe (4 x .5 EVL)
90° Elbow (1 x 5 EVL)
90° Tee (1 x 5 EVL)
21 ft. of Vertical Liner (21 x .5 EVL)
Termination Cap
Equivalent Vent Length
In the example system detailed above, the EVL was
29.5 which exceeds the maximum of 20 ft. for 3" pellet
vent pipe, thus 3" vent pipe should not be used in this
installation. However, since 4" pipe can support an EVL
up to 30, the use of 4" pipe would create a satisfactory
installation.
= 3 EVL
= 5 EVL
= 5 EVL
= 5 EVL
= 0 EVL
= 18 EVL
= 2 EVL
= 5 EVL
= 2 EVL
= 5 EVL
= 5 EVL
= 10.5 EVL
= 0 EVL
= 29.5 EVL