Harman P43 Installation Manual

Harman P43 Installation Manual

Freestanding pellet stove

Advertisement

INSTALLER: Leave this manual with party responsible for use and operation.
OwNER: Retain this manual for future reference.
NOTICE: SAVE THESE INSTRUCTIONS
Model(s):
P43 Freestanding Pellet Stove
Service parts list has been removed from this manual.
Refer to Owner's Manual or Individual service parts list.
!
Tested and approved for wood pellets and shelled field
corn fuel only. Burning of any other type of fuel voids
your warranty.
!
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Contact local building or fire officials about restrictions and
installation inspection requirements in your area.
1
Installation Manual
Installation and Appliance Setup
CAUTION
CAUTION
Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14
Please read this entire manual before
installation and use of this pellet fuel-
burning room heater.
Failure to follow these instructions
could result in property damage,
bodily injury or even death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
• Do not overfire - If any external part starts to glow,
you are overfiring. Reduce feed rate. Overfiring
will void your warranty.
• Comply with all minimum clearances to
combustibles as specified. Failure to comply
may cause house fire.
wARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
stove.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other
flammable materials.
• Keep clothing, furniture, draperies and other flammable
materials away.
NOTE
To obtain a French translation of this manual, please
contact your dealer or visit www.harmanstoves.com
Pour obtenir une traduction française de ce manuel, s'il
vous plaît contacter votre revendeur ou visitez www.
harmanstoves.com
wARNING
3-90-04301i

Advertisement

Table of Contents
loading

Summary of Contents for Harman P43

  • Page 1 To obtain a French translation of this manual, please Check building codes prior to installation. contact your dealer or visit www.harmanstoves.com • Installation MUST comply with local, regional, state and national codes and regulations. Pour obtenir une traduction française de ce manuel, s’il • Contact local building or fire officials about restrictions and vous plaît contacter votre revendeur ou visitez www. installation inspection requirements in your area. harmanstoves.com Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 2: Table Of Contents

    I. Fire Safety ........19  = Contains updated information J. Inspect Appliance & Components ....19 Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 3: Installation Standard Work Checklist

    Electrical Section 1 (Pg. 4) 120VAC unswitched power provided to the appliance. ________________________________ Appliance Setup Section 5 (Pg. 20-21) All packaging and protective materials are removed ________________________________ Accessories installed properly ________________________________ Manual bag and all it’s contents are removed from inside the appliance and given to party responsible for use and operation ________________________________ Started appliance and verified that all motors and blowers operate as they should. ________________________________ Hearth and Home Technologies recommends the following: Photographing the installation and copying this checklist for your file. This checklist remain visible at all times on the appliance until the installation is complete. Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed __________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Comments communicated to party responsible____________________ by ________________________ on __________ (Builder / Gen Contractor) (Installer) (Date) Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 4: Product Specific And Important Safety Information

    Harman® is a registered trademark of Hearth & Home Fuel: Wood Pellets or Shelled Corn Technologies. Shipping weight: 250 lbs *BTU output will vary, depending on the brand of fuel you use in your appliance. Consult your Harman® dealer for best results. Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 5: Getting Started

    • Insulated exterior chase in cooler climates • Avoid outside wall Windward Leeward Multi-level Roofs Recommended: NOT recommended: Outside Air Intake Outside Air Intake on windward side on leeward side Figure 2.1 Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 6: Tools And Supplies Needed

    Call a qualified service technician to inspect the appliance and to replace any part of the control system which has been under water. Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 7: Appliance Dimension Diagram

    Clearances A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. Outside Air Intake 5 1/8" 22" 20 3/4" Figure 3.1 Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 8: Clearances To Combustibles

    Alternate floor protector dimension may be used as long as they satisfy the measurement requirements shown below. Minimum size floor protection for a corner installation hearth pad is 36" x 36". 9"(228mm) 2"(51mm) *10" (254mm) *16" (406mm) 36"(914mm) *10" (254mm) with side shields 9" (228mm) With or Without Side Shields *16" (406mm) without side shields Figure 3.2 Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 9: Floor Protection

    Minimum Size floor protection (USA) is 32 " wide By 33" deep (825mm X 838mm). *Floor protection dimensions for the front and sides are measured from the appliance door opening in The United States. In Canada, the side dimension is measured from the widest part of the appliance. Floor Protection Canada Requirements Sides 6" 200mm Front 6" 450mm Rear 6" 200mm NOTE: Measurement "L" is measured from the pedestal base in the US ONLY NOTE: Measurement "K" is measured from the glass in the US ONLY CANADA loor protector Figure 3.3 Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 10: Termination Location And Vent Information

    Keep combustible materials (such as grass, leaves, etc.) at least 3 feet away from the flue outlet on the outside of the building. 3 Ft. to Combustibles Figure 4.2 Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 11 Kaowool, mineral wool or an equivalent non- combustible insulation is recommended to be installed on top of the sealing plate to reduce the possibility of condensation. The connector pipe should extend through the smoke chamber to the base or into the first flue tile. Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer. Be sure to design the venting so that it can be easily cleaned. Figure 4.4 Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 12 #6 Installing into an existing chimney (Figure 4.6) w/Full liner This method provides excellent venting for normal operation. This method also provides natural draft in the event of a power failure. In some places in the US and Canada it is required that the vent pipe extend all the way to the top of the chimney. Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer. The pipe or liner inside the chimney should be 4" diameter. In this method a cap should also be installed on the chimney to keep out rain. Figure 4.6 Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 13 Area within dotted circle represents the minimum clearance to combustible materials such as shrubbery, Seal pipe joints with silicone or aluminum tape in addition to mulch or tall grasses. the sealing system used by the manufacturer. Note: Do not place joints within wall pass-through. min. wall to outlet 12" Figure 4.9 Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 14: Chimney Diagram

    F. The clearance to an outside corner is 11" from center of shall conform to CAN/CSA-B365. (if in Canada) pipe. G. The clearance to an inside corner is 12". H. A vent must not be installed within 3 feet (90 cm) above a gas meter/regulator assembly when measured from the horizontal center-line of the regulator. Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 15: Venting & Use Of Elbows

    4" stainless steel flex vent piping is only allowed for use in masonry fireplaces and chimneys or factory built wood burning fireplaces with class A metal chimneys. All pellet vent pipe must be secured together either by means provided by pipe manufacturer or by 3 screws at each joint. Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 16: Outside Air

    HVAC professional to determine the ventilation demands for your house. To install outside air use 3". non-combustible flex pipe Figure 4.13. There is a break-away hole on the rear panel of the Termination Cap P43 stove which must be removed before connecting the part# 1-10-09542 flex pipe. Figure 4.12. The pipe should be run outside and terminate to the side or below the vent pipe outlet so the flue outlet is more than 12" from the inlet cover. The Termination Cap should be used to keep birds, rodents, etc. out of the pipe Figure 4.13. Figure 4.13 You may choose to use the optional Direct Vent Wall Pass- through Kit which incorporates the venting pass-through and outside air inlet into one component. Figure 4.14. Direct Vent Wall Pass-through Kit (Part #1-00-677177) Figure 4.14 Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 17: Locating Your Appliance And Chimney

    NOTICE: Hearth & Home Technologies assumes no chart below. If you have a lower reading than you find on responsibility for the improper performance of the chimney the chart, your appliance does not have adequate draft to system caused by: burn the fuel properly. • Inadequate draft due to environmental conditions Minimum Vacuum Requirements: .35 - .55 • Downdrafts • Tight sealing construction of the structure Prior to installing the flue pipe, connect a draft meter. (The • Mechanical exhausting devices draft meter must have a minimum range of 0 - .5”) Record the first reading. Connect flue pipe to stove and be sure all doors and windows in the home are closed. Record the second draft reading _______. If the second reading is more than .05” lower than the first reading, check for possible restrictions or the need for outside air. For more information on the draft test procedure, refer to Page 21 Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 18: Avoiding Smoke & Odors

    House demand may consume the air needed for the appliance. It may be necessary to add additional ventilation to the space in which the pellet appliance is located. Consult with your local HVAC professional to determine the ventilation demands for your house. Vent Pipe Be sure to use approved pellet vent pipe wall and ceiling pass- through fittings to go through combustible walls and ceilings. Be sure to use a starting collar to attach the venting system to the stove. The starting collar must be secured to the flue stub with at least three screws, and sealed with high temp silicone caulking. 4" stainless steel flex vent piping is only allowed for use in masonry fireplaces and chimneys or factory built woodburning fireplaces with class A metal chimneys. Pellet venting pipe (also known as Type L vent) is constructed of two layers with air space between the layers. This air space acts as an insulator and reduces the outside surface temperature to allow a clearance to combustibles of only 1 inch. The sections of pipe lock together to form an air tight seal in most cases; however, in some cases a perfect seal is not achieved. For this reason and the fact that the P43 operates with a positive vent pressure, we specify that the joints also be sealed with silicone. Where passing through an exterior wall or roof, be sure to use the appropriate pass-through device providing an adequate vapor barrier. Venting manufacturers generally provide these pass-through devices. Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 19: Fire Safety

    • Installation other than as instructed by Hearth & Home Technologies. • Installation and/or use of any component part not approved by Hearth & Home Technologies. • Operating appliance without fully assembling all components. • Do NOT Overfire. Or any such action that may cause a fire hazard. Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 20: Appliance Setup

    Do NOT use makeshift compromises when installing this appliance, serious consequences may result. Figure 5.2 With any hearth appliance, installation of smoke detectors is recommended on every level of the home. Flame guide Possible causes of smoke detector activation: Paint curing process - Open a window near the appliance for the first few hours of burning. Exhaust being drawn back inside the dwelling - Outside air connection to the appliance is necessary. Vent leakage - All interior seams and joints should be sealed with silicone where applicable. Follow vent manufacturers instructions for proper sealing. Figure 5.3 Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 21: Room Sensor

    T h e s m a l l s t r a i g h t the left rear corner of the firebox on screwdriver slot is plastic; the pedestal base. therefore, the unit can be adjusted while in Figure 5.5 operation. Connect the power cord to a 120 VAC, 60Hz grounded receptacle. (A surge protector is recommended to protect the circuit board.) Also be sure that the polarity of the outlet that the stove is plugged into is correct. Figure 5.4 Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 22: Reference Materials

    USE OF IMPROPER FUELS, FIRE STARTERS OR ALTERING THE STOVE FOR HIGHER HEAT OUTPUT MAY CAUSE DAMAGE TO THE STOVE AND COULD RESULT IN A HOUSE FIRE. USE ONLY APPROVED FUELS AND OPERATION GUIDELINES Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 23: Wiring Diagram

    B. wiring Diagram Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...
  • Page 24 Harman®, a brand of Hearth & Home Technologies Inc. 352 Mountain House Road, Halifax, PA 17032 www.harmanstoves.com Please contact your Harman® dealer with any questions or concerns. For the location of your nearest Harman® dealer, please visit www.harmanstoves.com. Printed in U.S.A. - Copyright 2012 Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14 3-90-04301i...

Table of Contents