Location Requirements - Jenn-Air JB36NXFXLW Installation Manual

Bottom mount
Hide thumbs Also See for JB36NXFXLW:
Table of Contents

Advertisement

Available languages

Available languages

RC Hinge Cover Trim
W10199873—42" SxS
W10199875—48" SxS
W10202875—36" BM
(Right)
W10202510—42" FDBM
(Right)
Panel templates
W10222281—SxS
W10222279—BM
W10222283—Grille
Installation block
W10234156
FC Hinge Cover Trim
W10199886—42" SxS
W10199888—48" SxS
W10202877—36" BM (Left)
W10202511—42" FDBM (Left)
Handle Side Door Trim
W10167367—SxS
W10188556—BM (Left)
W10202604—BM (Right)
W10202478—FDBM (Right)
W10202480—FDBM (Left)
Grille—Bottom / Skirt—Grille
W10189198 / W10188549—42" BM
W10189196 / W10199547—36" BM
W10182718 / W10188551—48" SxS
W10182717 / W10188549—42" SxS

Location Requirements

WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from refrigerator.
Failure to do so can result in death, explosion, or fire.
IMPORTANT:
Observe all governing codes and ordinances.
It is recommended that you do not install the refrigerator near
an oven, radiator, or other heat source.
Do not install in a location where the temperature will fall
below 55°F (13°C).
Floor must support the refrigerator weight, more than 600 lbs
(272 kg), door panels and contents of the refrigerator. Flooring
under refrigerator must be at same level as the room. Face of
cabinetry must be plumb.
Ceiling height must allow for side tipping radius. See "Tipping
Radius."
Location should permit door to open fully. See "Door Swing
Dimensions."
Location must permit top grille removal. See "Opening
Dimensions."
Opening Dimensions
IMPORTANT:
The width of the opening (Width A), from side to side, must be
as specified for your model, for at least 2" (5.08 cm) back from
the face of the cabinet.
NOTE: If your opening does not meet this requirement, you
will need to make modifications.
A solid soffit or wall cabinet must be installed 84" (213.4 cm)
above the floor. If the solid soffit is higher than 84" (213.4 cm)
or one is not available, then the refrigerator must be braced.
If the anti-tip boards are needed, they must be attached to the
rear wall studs so that there is 84" (213.4 cm) from the bottom
of the anti-tip board to the floor. See "Install Anti-Tip Boards"
for more information.
For a fully integrated installation, a minimum of 6" (15.24 cm)
of open space above the refrigerator is required. See "Fully
Integrated Installation." Anti-tip boards are required. See
"Install Anti-Tip Boards" for more information.
A grounded 3 prong electrical outlet should be located within
a specified number of inches from the right-hand side
cabinets or end panel. See the chart following the graphic for
the number of inches required for your model. For more
information, see "Electrical Requirements."
7