MT. VERNON AE
B. Through The Wall
Horizontal termination cap must be a minimum of 6 inches.
(152mm) from the wall. Approved for mobile home installa-
tions. Must use 3 or 4 inch (76-102mm) "L" or "PL" Listed
pellet venting or Listed double wall pipe and a Quadra-Fire
Outside Air Kit in mobile homes.
Straight Out
Figure 14.1
45 Degree
Figure 14.2
14
6 in.
(152mm)
Minimum
From Glass
Illustration shows venting going in both directions.
Choose which one is best for your installation.
6 in. (152mm)
Minimum
NOTE:
In Canada, where passage through a wall or partition of com-
bustible construction is desired, the installation shall conform
to CAN/CSA-B365
2 in.
(51mm)
Minimum
Non-combustible Hearth Pad
Wall
Thimble
2 in.
(51mm)
Minimum
7034-277E
Horizontal
W all
T ermination
Thimble
Cap
6 in.
(152mm)
Minimum
6 in. (152mm)
Minimum
2 in. (51mm)
Minimum
May 5, 2015