Drain Valve And Extension - Henny Penny PFG-690 Technical Manual

Pressure fryer
Table of Contents

Advertisement

2-24. DRAIN VALVE
AND EXTENSION
Oct. 2002
The drain valve opens when drain valve handle is pulled out
and drains the shortening out of the pot.
1. Using a 3/8" socket, remove the nuts securing the drain
switch bracket, and pull the bracket from the studs.
2. Remove the nut securing the drain handle and pull the
handle from the drain valve.
3. Using a large adjustable wrench, unscrew drain valve and
extension from the unit.
4. Replace the drain valve and extension.
5. Replace the drain switch bracket.
6. Adjust the microswitch to be no more than 1/8" (3 mm)
from the shaft of the drain valve.
HINT: Listen for audible click of switch while pulling
drain valve handle.
2-23