1-3. TROUBLESHOOTING
(Continued)
Problem
Foaming or boil-
ing over of
shortening
Shortening will
not drain from
frypot
Shortening leaking
through drain
valve
Oct. 2002
Cause
SHORTENING FOAMING/DRAINING SECTION
Water in shortening
Condensation line stopped up
Improper or bad
shortening
Improper fi
tering
l
Cold zone full of cracklings
Improper rinsing after
cleaning the fryer
Drain valve clogged with
crumbs
Obstruction in drain
Faulty drain valve
1-10
Model 690
Correction
At end of a cook cycle,
drain shortening and clean
frypot; add fresh
shortening
Remove and clean conden-
sation line
Use recommended
shortening
Refer to the procedure
covering filtering the
shortening
Filter shortening
Clean and neutralize the
frypot; rinse with vinegar
to remove the alkaline, then
rinse with hot water, and
dry frypot
Open valve, push cleaning
rod through drain open-
ing from inside of frypot
Remove obstruction
Replace drain valve

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents