2-22. DRAIN VALVE
AND EXTENSION
1103
The drain valve opens when the drain valve handle is pulled
out and drains the shortening out of the pot.
Replacement
1. Using a 3/8" socket, remove the nuts securing the drain
switch bracket, and pull the bracket from the studs.
2. Remove the nut securing the drain handle and pull the
handle from the drain valve.
3. Using a large adjustable wrench, unscrew the drain valve
and extension from the unit.
4. Replace the drain valve and extension.
5. Replace the drain switch bracket.
6. Adjust the microswitch to be no more than 1/8" (3 mm)
from the shaft of the drain valve.
HINT: Listen for audible click of switch while pulling drain
valve handle.