This fireplace must be vented to the outside. The venting system must NEVER be
attached to a chimney serving a separate solid fuel burning appliance. Each gas
appliance must use a separate vent system. Do not use common vent systems.
Horizontal sections of this vent system require a minimum of 3" clearances to
combustibles at the top of the flue and 1" clearance at the sides and bottom until
the flue penetrates the outside wall. A minimum 1" clearance all around the flue is
acceptable at this point of penetration.
Vertical sections of this vent system require a minimum of 1" clearance to combustibles
on all sides of the pipe.
A Minimum of 3" Clearance
to the Top Is Required Along
Horizontal Length until Flue
Pipe Penetrates Outside Wall.
54D5032
3"
Figure 7 - Combustible Clearances for Vent Pipe
A Minimum 1" Clearance to
Combustibles Permitted All
Around Flue at Outside Wall
1"
1"

VENT INSTALLATION

1 "
3 "
1 "
1 "