Majestic 40ICFDVLNTSC Installation And Operating Instructions Manual

Clean face direct vent fireplace insert

Advertisement

Installation and

Operating Instructions

WARNING
IF The INFORMATION IN TheSe INSTRuCTIONS IS NOT
FOLLOWeD exACTLy, A FIRe OR exPLOSION MAy
ReSuLT CAuSING PROPeRTy DAMAGe, PeRSONAL
INjuRy OR LOSS OF LIFe.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
WhAT TO DO IF yOu SMeLL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
WARNING: Improper installation, adjustment, alteration,
services or maintenance can cause injury or property
damage. Refer to this manual. For assistance or additional
information consult a qualified installer, service agency
or the gas supplier.
This appliance may be installed in an aftermarket*,
permanently located, manufactured home (uSA only) or
mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified
kit is used.
* Aftermarket: Completion of sale, not for purpose of resale, from the
manufacturer.
Clean Face Direct Vent
Fireplace Insert
Models:
40ICFDVLNTSC,
40ICFDVLPTSC,
40ICFDVCNTSC
4734
40ICFDV insert cover
Due TO hIGh TeMPeRATuReS, The APPLIANCe
ShOuLD Be LOCATeD OuT OF TRAFFIC AND
AWAy FROM FuRNITuRe AND DRAPeRIeS.
ChILDReN AND ADuLTS ShOuLD Be ALeRTeD
TO T h e h A Z A R D S O F h I G h S u R FA C e
TeMPeRATuRe AND ShOuLD STAy AWAy TO
AVOID BuRNS OR CLOThING IGNITION.
yOuNG ChILDReN ShOuLD Be SuPeRVISeD
WheN They ARe IN The SAMe ROOM AS The
APPLIANCe.
CLOThING OR OTheR FLAMMABLe MATeRIAL
ShOuLD NOT Be PLACeD ON OR NeAR The
APPLIANCe.
KeeP The ROOM AReA CLeAR AND FRee FROM
COMBuSTIBLe MATeRIALS, GASOLINe, AND
OTheR FLAMMABLe VAPORS AND LIquIDS.
INSTALLeR: Leave this manual with the appliance.
CONSuMeR: Retain this manual for future refer-
ence.
20304734 3/13 Rev. 3

Advertisement

Table of Contents
loading

Summary of Contents for Majestic 40ICFDVLNTSC

  • Page 1: Operating Instructions

    Clean Face Direct Vent Fireplace Insert Models: 40ICFDVLNTSC, 40ICFDVLPTSC, 40ICFDVCNTSC Installation and Operating Instructions WARNING IF The INFORMATION IN TheSe INSTRuCTIONS IS NOT FOLLOWeD exACTLy, A FIRe OR exPLOSION MAy ReSuLT CAuSING PROPeRTy DAMAGe, PeRSONAL INjuRy OR LOSS OF LIFe.
  • Page 2: Table Of Contents

    CONTeNTS 40ICFDV Gas Fireplace Insert Thank you and congratulations on your purchase of a Majestic Fireplace Insert PLeASe ReAD The INSTALLATION AND OPeRATION INSTRuCTIONS BeFORe uSING The APPLIANCe! IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
  • Page 3: Important Safety Information

    IMPORTANT SAFeTy INFORMATION 40ICFDV Gas Fireplace Insert OWNeR INSTALLeR Please retain these instructions for future reference. Please leave these instructions with the appliance. • Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. •...
  • Page 4: Code Approval

    IMPORTANT SAFeTy INFORMATION & CODe APPROVAL 40ICFDV Gas Fireplace Insert IMPORTANT: 12. Do not use this fireplace to cook food or burn paper or PLeASe ReAD The FOLLOWING other objects. CAReFuLLy 13. Never place anything on top of fireplace. It is normal for fireplaces fabricated of steel 14.
  • Page 5: Product Features Product Specifications

    ANSI Z223.1/NFPA 54 and/or local codes having juris- Model Fuel BTu/h BTu/h Front Rear diction. 40ICFDVLNTSC Nat. 39,000 26,000 In Canada, please consult provincial and/or local authori- 40ICFDVLPTSC 35,000 29,000 1.2 mm 1.3 mm ties having jurisdiction for installation at elevations above 40ICFDVCNTSC Nat.
  • Page 6: Insert Dimensions

    INSeRT DIMeNSIONS 40ICFDV Gas Fireplace Insert ” (621 mm) 13 ” (337 mm) ” 12 ” (56 mm) (318 mm) ” (144 mm) " 18 " (586 mm) (460 mm) ” (668 mm) 2 ” 29 ” (740 mm) (57 mm) Figure 2 - 40ICFDV Fireplace Insert Dimensions 4734...
  • Page 7: Installation Information

    GeNeRAL INSTALLATION INFORMATION 40ICFDV Gas Fireplace Insert BeFORe yOu START Read this homeowner manual thoroughly and follow all your remote control receiver must "learn" instructions carefully. Inspect all contents for shipping the signal code from your hand-held trans- damage and immediately inform your dealer if any damage is found.
  • Page 8: Clearances

    CLeARANCeS 40ICFDV Gas Fireplace Insert INSeRT CLeARANCeS No combustibles (ie: drapes, doors) may be within, or swing within 36" of the front of the insert. Finish Wall 12" (305 mm) 12” (305 mm) Maximum Depth 14" Side Wall Noncombustible (355 mm) Material Required 14”...
  • Page 9: Installation

    INSTALLATION 40ICFDV Gas Fireplace Insert INSeRT PLACeMeNT ReMOVe COMMAND CeNTeR BRACKeT • The insert must be placed within a code-conforming In order to fit insert into a smaller opening, the command masonry fireplace or a tested and listed zero-clear- center bracket may be removed. Refer to Pages 6 and 9 ance (UL-127, solid fuel) fireplace.
  • Page 10: Zero-Clearance Fireplace Requirements

    INSTALLATION 40ICFDV Gas Fireplace Insert ZeRO-CLeARANCe (MeTAL) FIRePLACe Insulation RequIReMeNTS • The damper and grate must be removed. • The smoke shelf, internal baffles, screen, refractory and Shelf metal or glass doors may be removed (if applicable). • Do not remove or alter the insulation or any structured rigid frame members (metal sides, floor, door frames, Masonry Lining or Refractory face of the fireplace, etc.).
  • Page 11: Venting Installation

    VeNTING INSTALLATION 40ICFDV Gas Fireplace Insert VeNTING RequIReMeNTS Read all instructions completely and thoroughly before attempting installation. • Failure to do so could result in serious injury, Make sure the exhaust pipe on heater property damage or loss of life. Operation of connects to exhaust portion of cap.
  • Page 12: Altitude Considerations

    VeNTING INSTALLATION 40ICFDV Gas Fireplace Insert ALTITuDe CONSIDeRATIONS Failure to adjust air shutter properly may This heater has been tested at altitudes ranging from sea lead to improper combustion which can level to 4,500 feet (1,370 m). In this testing, heater with create a safety hazard.
  • Page 13: Venting Configurations

    VeNTING INSTALLATION 40ICFDV Gas Fireplace Insert VeNTING CONFIGuRATIONS Termination Kits (Refer to Page 11) Exhaust Inlet 3" (75 mm) Exhaust UL 1777 Gas Liner 3" (75 mm) Inlet Recommended block-off plate (noncombustible metal). Prevents odors from chimney entering room. UL 127 Solid Fuel Z.C Fire- FP1924 Figure 11 -...
  • Page 14: Insert Installation

    GLASS FRAMe ReMOVAL 40ICFDV Gas Fireplace Insert GLASS FRAMe ReMOVAL 1. Before installation, the glass frame removal tool must WARNING be removed from the side of the unit. As you face the front of the unit, the glass frame removal tool is located on the right side.
  • Page 15: Brick Panel Installation

    INSTALLATION 40ICFDV Gas Fireplace Insert INTAKe/exhAuST MANIFOLD ReMOVAL IMPORTANT: The fireplace must have an approved brick AND VeNT INSTALLATION kit or porcelain panel kit installed before operation. BRICK PANeL INSTALLATION The intake/exhaust manifold is shipped attached to insert. It may be removed to allow tight installation. Figure 13 1.
  • Page 16: Check Gas Type

    INSTALLATION 40ICFDV Gas Fireplace Insert INSTALLATION ITeMS NeeDeD The unit is shipped from the factory without a baffle installed. On the natural gas units, the baffle should be Make sure you have the items listed below before install- sufficient for venting up to 20 feet (6 m) off the top of the ing appliance.
  • Page 17 INSTALLATION 40ICFDV Gas Fireplace Insert A manual shut-off valve is factory installed Only persons licensed to work with gas upstream of the appliance. union tee and piping may make the necessary gas con- plugged 1/8" NPT pressure tapping point nections to this appliance. should be installed upstream of the appli- ance.
  • Page 18: Check Gas Pressure

    CheCK GAS PReSSuRe 40ICFDV Gas Fireplace Insert 1. Check gas type. The gas supply must be the same as Pressure Inlet stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance.
  • Page 19: Electrical Installation

    eLeCTRICAL INSTALLATION 40ICFDV Gas Fireplace Insert eLeCTRICAL WIRING This insert will work without any electrical supply. Electricity is only needed to operate blower. 300 Watts To Outlet A/C Module Verify proper operation after servicing. Pilot Optional Aux. 300 Watts 300 Watts RF Receiver A/C Module ON/OFF Button...
  • Page 20: Log Placement

    LOG PLACeMeNT 40ICFDV Gas Fireplace Insert Before you begin - This unit is supplied with nine (9) The positioning of the logs is critical to ceramic fiber logs. Do not handle these logs with your bare the safe and clean operation of this heater. hands.
  • Page 21 LOG PLACeMeNT 40ICFDV Gas Fireplace Insert Log #1 3. Place log #1 on the pins provided on the back of the bracket surrounding both burners. Figure 23 Figure 23 LG1142 4. Place log #2 on the two (2) pins provided on the LG1142 right front of the front burner.
  • Page 22 LOG PLACeMeNT 40ICFDV Gas Fireplace Insert 7. Place log #5 on top of the key pro- Log #5 vided in the middle of log #1. Rest the fork end of the log on the front burner between logs #2 & 4. Figure 26 Log #6 8.
  • Page 23: Decorative Glass & Stone Installation

    GLASS & STONe INSTALLATION 40ICFDV Gas Fireplace Insert DeCORATIVe GLASS & STONe INSTALLA- TION Use caution when handling glass. 3. Place stones on glass randomly as desired. Figure 29 1. Remove glass frame using the cam tool supplied with unit. 4.
  • Page 24: Surround Installation

    SuRROuND INSTALLATION 40ICFDV Gas Fireplace Insert Insert INSTALL SuRROuND 1. Remove glass frame assembly. Page 14, Figure 12 2. Align surround holes with insert and Surround attach with screws provided. 3. Re-attach glass door assembly. FP2995 Mounting Screws Figure 30 - Install Surround Glass Door Assembly...
  • Page 25 SuRROuND INSTALLATION 40ICFDV Gas Fireplace Insert Figure 33 - Figure 34 - Small Surround with Side FP2953 Trimmable Surround FP2954 Control Access FP2953 sm surr 3 side ctrl FP2954 contemporary surround 20304734...
  • Page 26: Operating Instructions

    OPeRATING INSTRuCTIONS 40ICFDV Gas Fireplace Insert FOR yOuR SAFeTy ReAD BeFORe LIGhTING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of lie. A. This appliance is equipped with an ignition device which automatically lights the pilot. Refer to the instructions.
  • Page 27: Operating Instructions

    OPeRATING INSTRuCTIONS 40ICFDV Gas Fireplace Insert OPeRATING INSTRuCTIONS 1. STOP! Read the safety information above. 2. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3. With five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B"...
  • Page 28: Adjust The Air Shutter (Front Burner)

    AIR ShuTTeR ADjuSTMeNT (NATuRAL GAS ONLy) 40ICFDV Gas Fireplace Insert ADjuST The AIR ShuTTeR (FRONT/ReAR BuRNeR) 3. Remove four (4) screws holding burner in place and The venturi of the front burner is equipped with an air slide burner to the left and up and out of unit, allowing shutter.
  • Page 29: Signature Command System Operation

    SIGNATuRe COMMAND SySTeM OPeRATION INSTRuCTIONS 40ICFDV Gas Fireplace Insert To Thermopile RF Receiver FeATuReS ON/OFF To Sensor Command Center To Sparker • Easy Access Function Operation and System Configura- tion NG/LP Conversion • Operation Confirmation/Fault Diagnostic Indications (LED/Buzzer) • ON/OFF/HI/Med/Low Operation To Command Center Control •...
  • Page 30 SIGNATuRe COMMAND SySTeM OPeRATION INSTRuCTIONS 40ICFDV Gas Fireplace Insert NOTe: By disabling this feature, your fireplace may con- SySTeM CONFIGuRATION/SeTuP tinue to operate unattended. All System configuration/setup is done on the Command 2. When the master switch is in the ON position (“-”), press- Center or Control Board.
  • Page 31: Signature Command System Operation Instructions

    SIGNATuRe COMMAND SySTeM OPeRATION INSTRuCTIONS 40ICFDV Gas Fireplace Insert FuNCTIONS/OPeRATION (with Command Center) Turning on the fireplace 3. The third press on OFF will turn off the main burner. In 1. Turn on the master switch and wait for a beep. standing pilot configuration, the pilot will stay;...
  • Page 32: Touch Screen Remote Control Operation

    TOuCh SCReeN ReMOTe CONTROL OPeRATION 40ICFDV Gas Fireplace Insert Due to the sensitive temperature monitoring components in the transmitter, it is necessary to allow the transmitter to stabilize to room tem- perature before accurate room temperatures are displayed. If the transmitter is activated from a severe cold condition, allow 15 minutes for accurate temperature readings to appear on the LCD display.
  • Page 33 TOuCh SCReeN ReMOTe CONTROL OPeRATION 40ICFDV Gas Fireplace Insert Setting Privacy Code on Transmitter: Master Switch Figure 44 The remote transmitter privacy code is preset in factory. In the event of activation or interference from other nearby transmissions, change the code using the following procedures (learn function must be performed after changing the code):...
  • Page 34 TOuCh SCReeN ReMOTe CONTROL OPeRATION 40ICFDV Gas Fireplace Insert Time to zero Or 1. Press the ON/up button to turn on the fireplace. The c. Slide down on the arrow buttons to exit TIMER flame icon on the LCD displays mode and shut off the fireplace.
  • Page 35 TOuCh SCReeN ReMOTe CONTROL OPeRATION 40ICFDV Gas Fireplace Insert the flame height according to the difference between the effect right away; if the fireplace is off, the receiver will Set temperature and the Room temperature. There is no remember this setting and the blower is still off (see manual flame height adjustment.
  • Page 36: Safety Features

    TOuCh SCReeN ReMOTe CONTROL OPeRATION 40ICFDV Gas Fireplace Insert 3. Press the light button again to confirm the setting. The n Safety Features new setting will be transmitted to the receiver. 1. Low Battery Detection 4. After the signal is sent, the On/up and Off/down but- When low battery condition occurs, the transmitter will tons become flame height controller again.
  • Page 37 TOuCh SCReeN ReMOTe CONTROL OPeRATION 40ICFDV Gas Fireplace Insert n using the Mounting Base The transmitter comes with a mounting base which allows you to hang the transmitter on the wall. 1. Secure the mounting base on the wall with supplied screws.
  • Page 38: Cleaning And Maintenance

    CLeANING and MAINTeNANCe 40ICFDV Gas Fireplace Insert You should clean the glass after the first two weeks of use. Make sure the master switch on the command center is After that, you should clean the glass no more than two or in the “OFF”...
  • Page 39: Firebox Cleaning

    CLeANING and MAINTeNANCe 40ICFDV Gas Fireplace Insert FIReBOx CLeANING 1. Carefully remove log set, and embers from combustion • Allow logs to cool completely before chamber. cleaning. Logs reach high tempera- 2. Vacuum burner compartment thoroughly. tures. 3. Vacuum any dust off logs. •...
  • Page 40: Yearly Service Procedure

    MAINTeNANCe 40ICFDV Gas Fireplace Insert yeARLy SeRVICe PROCeDuRe 5. Replace log set and rock wool according to instruc- Failure to inspect and maintain heater may lead to improper tions on Pages 20-23. Replace glass door. Make sure combustion and a potentially dangerous situation. A quali- gasket along perimeter of glass contacts face of firebox fied technician should do the following once a year.
  • Page 41: Troubleshooting

    TROuBLeShOOTING 40ICFDV Gas Fireplace Insert SIGNATuRe COMMAND SySTeM OPERATION FAULT ACTION DIAGNOSIS Using Battery polarity wrong? Re-install batteries battery? Make sure Command Install batteries and/or Battery voltage low? Change batteries Center and plug in the AC board No beep in about the control 8 seconds board are...
  • Page 42: Replacement Parts

    RePLACeMeNT PARTS 40ICFDV Gas Fireplace Insert 34a,b 44/47 42/45 43/46 4734 40ICFDV parts 20304734...
  • Page 43 RePLACeMeNT PARTS 40ICFDV Gas Fireplace Insert Ref. Description qty. 40ICFDVLNTSC 40ICFDVLPTSC 40ICFDVCNTSC 1. Log #1 20304768 20304768 2. Log #2 20304769 20304769 3. Log #3 20304770 20304770 4. Log #4 20304771 20304771 5. Log #5 20304772 20304772 6. Log #6...
  • Page 44 RePLACeMeNT PARTS 40ICFDV Gas Fireplace Insert Ref. Description qty. 40ICFDVLNTSC 40ICFDVLPTSC 40ICFDVCNTSC 45. Left Brick Liner - Tavern Brown 20304758 20304758 46. Right Brick Liner - Tavern Brown 20304757 20304757 47. Rear Brick Liner - Tavern Brown 20304756 20304756 48. Glass Door Assy...
  • Page 45: Optional Accessories

    RePLACeMeNT PARTS 40ICFDV Gas Fireplace Insert 5 a,b,c 1 a,b 7 a,b,c,d,e 8 a,b,c,d,e 6 a,b,c,d,e Optional Accessories Ref. Description 40ICFDV Square Face - Textured Black ICF40SFTB Square Face - Iron Age ICF40SFIA Small, 3-sided Surround 5/8" Deep - Black ICF40S3FB Small, 3-sided Surround 2"...
  • Page 46: For Massachusetts Residents Only

    40ICFDV Gas Fireplace Insert Massachusetts Residents Only — Please read and follow these special requirements NOTe ReGARDING VeNTeD PRODuCTS 2. Approved Carbon Monoxide Detectors. Each carbon This product must be installed by a licensed plumber or gas fitter monoxide detector as required in accordance with the above when installed within the Commonwealth of Massachusetts.
  • Page 47: Warranty

    40ICFDV Gas Fireplace Insert LIMITeD 10 yeAR WARRANTy Limited 10 year warranty The following components are warranted for 10 years from the date of purchase of the product: Firebox, Com- bustion Chamber, Heat Exchanger, Grate, Stainless Steel Burners, Glass (thermal breakage only), Ceramic Fiber Logs and Refractory Brick.
  • Page 48: Efficiencies

    40ICFDV Gas Fireplace Insert Based on CSA P.4.1-09 efficiency Ratings Model enerGuide Ratings D.O.e. Fireplace efficiency (%) (AFue%) 40ICFDVLNTSC 75.9 70.67 40ICFDVLPTSC 78.7 71.21 40ICFDVCNTSC 77.3 68.66 40ICFDVCNTSC 77.8 69.49 w/Propane Conversion Recherchez dans la brochure les caractéristique de rendement énergétique de foyer au gaz...

Table of Contents