VeNt INstAllAtIoN
horizontal sections of this vent system
require a minimum of 3" clearances
to combustibles at the top of the flue
and 1" clearance at the sides and
bottom until the flue penetrates the
outside wall. A minimum 1" clearance
all around the flue is acceptable at this
point of penetration. If vertical rise is
7Z\x" feet or higher when top venting,
the clearance to combustibles is 1" on
all sides of the horizontal run.
Vertical sections of this vent system
require a minimum of 1" clearance
to combustibles on all sides of the
pipe.
Figure 7 -
Combustible Clearances for Vent Pipe
54D0701
FP2095
FP2095
vent pipe clearance
DVB Series Direct Vent Gas Fireplace
this fireplace must be vented to the
outside. the venting system must
NeVeR be attached to a chimney
serving a separate solid fuel burning
appliance. each gas appliance must
use a separate vent system. Do not
use common vent systems.
A Minimum 3" Clearance to
the Top is Required Along
Horizontal Length until Flue
Pipe
Wall
1 "
3 "
1 "
1 "
Penetrates
Outside
A Minimum 1" Clear-
ance to Combustibles
Permitted All Around
Flue at Outside Wall
13