Component Testing

For accurate resistance and/or continuity checks, elec-
trically disconnect the component being tested from the
circuit (e.g. unplug the ignition switch connector before
doing a continuity check).
NOTE: For more component testing information, see
the Kubota Workshop Manual for 03 Series Diesel En-
gine.

Ignition Switch

The ignition (key) switch has three positions (OFF, RUN,
and START). The terminals are marked as shown. The
circuitry of the ignition switch is shown in the chart. With
the use of a multimeter (ohms setting), the switch func-
tions may be tested to determine whether continuity ex-
ists between the various terminals for each position.
Verify continuity between switch terminals.
SWITCH
NORMAL
POSITION
CIRCUITS
OFF
RUN
START
Electrical System (Rev. C)
OTHER
CIRCUITS
NONE
NONE
B + A + I
X + Y
B + S + I
NONE
When testing electrical components for continu-
ity with a multimeter (ohms setting), make sure
that power to the circuit has been disconnected.
B
SWITCH
Page 5 − 20
CAUTION
A
Y
S
I
X
Figure 3
HEX NUT
LOCK WASHER
Figure 4
OFF
45 °
Figure 5
Reelmaster 4000−D
KEY
RUN
45 °
START

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents