Preparing To Test The Components; Testing The Component - Toro Greensmaster eFlex 1800 Diagnostic Manual

Traction unit
Hide thumbs Also See for Greensmaster eFlex 1800:
Table of Contents

Advertisement

3. Finish the cleaning with a fiber bristle brush dipped
in isopropyl alcohol.
4. Gently wipe off the clean pins, terminals, and
components with a lint-free cloth dampened with
isopropyl alcohol.
5. When available, dry the components with dry, oil-free
compressed air (maximum air pressure 20 psig/137.895
kPa).
6. Ensure all connectors and components are clean and
dry prior to reassembly and testing.
Preparing to Test the
Components
1. Park the machine on a level surface.
2. Move the traction lever to the N
3. Move the kickstand into the J
Refer to
Using the Kickstand (page

Testing the Component

CAUTION
Performing continuity testing on electrical
components with the battery pack connected can
lead to severe electrical shock.
Disconnect the battery pack from the machine
before testing electrical components. Refer to
Disconnecting the Battery Pack (page
CAUTION
Wearing jewelry while troubleshooting or testing
the machine can be dangerous. Jewelry can cause a
short circuit or get caught on the machine, causing
serious injury.
Remove all jewelry, especially rings and watches,
before doing any electrical troubleshooting or
testing.
Important: The Greensmaster eFlex uses a 53-Vdc
battery-based electrical system. Actual measurements
of voltage will vary from 42 to 64 Vdc, depending on the
charge level of the battery pack.
Important: The machine frame is not used as an
electrical ground. Ground is distributed through the
machine wire harnesses.
Some components can be tested through the InfoCenter
display. Refer to the eFlex Service Manual, Chapter 4,
Diagnostics Screen.
position.
EUTRAL
S
position.
ACK
TAND
17).
17).
If diagnosis using the InfoCenter is not possible, remove
power from the machine by turning the key switch to
the O
position, removing the key from the switch, and
FF
disconnecting the battery pack. Refer to
Battery Pack (page
17).
For accurate resistance and/or continuity checks, electrically
isolate the component being tested by disconnecting all wiring
or removing it from the circuit).
Note: Refer to the eFlex Service Manual Chapter 4, Electrical
System.
Components Covered in the Component
Testing Procedures in the eFlex Service
Manual
Component
Detail
Fuse block
Fuse F1-1 (30 amp/80 volt), fuse F1-2 (3
amp/80 volt), fuse F1-3 (3 amp/80 volt)
Lithium battery
58V fuse replacement
pack fuse
Key switch
Key switch testing
Parking brake
Parking brake latch switch operation,
latch switch
testing, and removal/installation
Traction switch
Traction switch operation, testing, and
removal/installation
Reel-engage
Reel-engage switch operation, testing, and
switch
removal/installation
EZ-Turn switch
EZ-Turn switch testing
EZ-Turn sensor
EZ-Turn sensor testing
Speed-control
Speed-control potentiometer operation and
potentiometer
testing
Main contactor
Main contactor testing
Toro Electronic
Toro Electronic Controller information
Controller
(TEC-2401)
CAN-Bus
CAN-Bus termination resistor and resistor
termination
testing
resistor
15
Disconnecting the

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greensmaster eflex 21000404204043

Table of Contents