Hydraulic Oil Level Switch; Bridge Rectifier - Toro Reelmaster 4000?D Service Manual

Hide thumbs Also See for Reelmaster 4000?D:
Table of Contents

Advertisement

Hydraulic Oil Level Switch

The level switch is located on top of the hydraulic reser-
voir under the seat. It has an electrical connector from
the wiring harness with two black, a black/white, and a
orange wire.
1. Remove electrical connector from the level switch.
2. Unscrew sender from the cover, and remove it from
the reservoir.
Note: Float switch L1 is normally open when the tank
is dry (float down). Float switch L2 is normally closed
when the tank is dry (float down).
3. Position float switch L2 against its lower float stop.
4. Check for continuity between electrical connector
leads associated with the yellow wires.
5. Position float switch L2 against its upper float stop.
6. Check continuity between electrical connector
leads associated with the yellow wires. There should be
no continuity between connector leads.
7. Replace switch as necessary. Install switch to hy-
draulic reservoir.

Bridge Rectifier

Each rectifier (Fig. 22) contains four diodes which form
a single phase bridge rectifier circuit (Fig. 23). The
diodes are used for circuit protection from inductive volt-
age spikes when the alarm relay is deenergized.
Testing
The diodes can be individually tested using a digital
multimeter (ohms setting) and the table below.
Red Lead (+)
Black Lead (−)
on Terminal
on Terminal
AC1
+
AC2
+
AC1
AC2
Electrical System (Rev. C)
Continuity
+
YES
AC1
NO
+
YES
AC2
NO
AC1
YES
NO
AC2
YES
NO
1
2
4
1. Electrical connector
2. Level switch
3. Float switch
2
1. Bottom view
AC1
AC2
Page 5 − 28
5
3
L2
RED
YELLOW
L2
L1
YELLOW
RED
Figure 21
4. Lower float stop
5. Upper float stop
2
Figure 22
2. Side view
Figure 23
Reelmaster 4000−D
L1