Conversion Kit To Lp Or Ulpg - Regency GFI300LNG-R User Manual

Inbuilt
Table of Contents

Advertisement

INSTALLATION
Conversion Kit from NG to LP or ULPG
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
10. Remove 2 screws in location shown below to remove front bracket.
1. Unplug or disconnect the power source to the unit.
2. Shut off the gas supply and remove the gas connection from the valve.
3. Remove the faceplate, door frame, safety glass or screen.
4. Remove the glass door. (See door removal section in this manual).
5. Remove the logs. (See log section in this manual).
6. Remove the panels. (See panel section in this manual).
7. Remove the log tray, by removing 2 screws in locations shown below.
11. Remove pilot retainer clip with pliers and pull off the pilot cap to expose
the pilot orifice.
8. Lift log tray up and out to remove.
Pilot retainer clip
9. Remove burner - loosen screw on left side, remove screw from right side
- slide to the right and lift up and out to remove and discard
12. Remove burner orifice with a 1/2" wrench and discard. Use another wrench
to hold on to the elbow below the orifice.
Loosen
Remove
15
Regency GFI300L Gas Fireplace Inbuilt

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gfi300llp-rGfi300lulpg-r

Table of Contents