Lexmark Optra K 1220 Installation And User Manual page 118

Simm for ipds
Hide thumbs Also See for Optra K 1220:
Table of Contents

Advertisement

IPDS Timeout = 15 seconds to 10 minutes (when using a MarkNet S only)
If you selected the IPDS Timeout value of Host Controlled to allow the host to
directly control ending (disconnecting) a LAN session, go to IPDS Timeout =
Host Controlled on page 117.
If you selected an IPDS Timeout value of 15 seconds to 10 minutes to allow the
printer IPDS emulation to determine when an IPDS LAN session times out,
follow the steps below to correct the problem.
1.
Adjust the MarkNet S end-of-job timeout value to 0 (disabled). See 5 Using
the SIMM for IPDS with a MarkNet Adapter or MarkNet Print Server on
page 65 for additional information.
2.
Change the host port setting to 9600. Refer to IPDS Timeout on page 40 for
further information on the selection of ports.
3.
Correct the appropriate host timer/timeout value as shown below.
Note:
PSF/400 with OS/400 V3R1 or V3R6
WRKAFP2: Inactivity Timer (INACTTMR)
PSF/400 with OS/400 V3R2, V3R7, V4R1, or V4R2
CRTPSFCFG: Release Timer (RLSTMR)
PSF/MVS
PSF Startup Proc: Disconnect Interval (DISCINTV)
PSF/2
TCP/IP Settings: Connect Timeout
Tuning Option: Job Interval Shutdown Timer
PSF/AIX
SMIT Printer Def: Connect Timeout
118
The host timer/timeout values below should not be used with a
host port value of 9100 or 9102.
*NOMAX
*NOMAX
0
0
9999
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Optra sOptra se 3455

Table of Contents