Functions - Daikin FTK09NMVJU Engineering Data

Cooling only / heat pump - seer 18 models
Hide thumbs Also See for FTK09NMVJU:
Table of Contents

Advertisement

Functions

2. Functions
Category
Basic
Inverter (with inverter power control)
Function
Operation limit for cooling (°CDB)
Operation limit for cooling (°FDB)
Operation limit for heating (°CWB)
Operation limit for heating (°FWB)
PAM control
Standby electricity saving
Compressor
Oval scroll compressor
Swing compressor
Rotary compressor
Reluctance DC motor
Comfortable
Power-airflow flap (horizontal blade)
Airflow
Power-airflow dual flaps
Power-airflow diffuser
Wide-angle louvers (vertical blade)
Auto-swing (up and down)
Auto-swing (right and left)
3-D airflow
COMFORT AIRFLOW operation
Comfort
Auto fan speed
Control
Indoor unit quiet operation
NIGHT QUIET mode (automatic)
OUTDOOR UNIT QUIET operation
(manual)
INTELLIGENT EYE operation
Quick warming function
Hot-start function
Automatic defrosting
Operation
Automatic operation
Program dry function
Fan only
Lifestyle
New POWERFUL operation
Convenience
(non-inverter)
Inverter POWERFUL operation
Priority-room setting
COOL / HEAT mode lock
HOME LEAVE operation
ECONO operation
Indoor unit ON/OFF button
Signal receiving sign
R/C with back light
Temperature display
Note:
: Available
— : Not available
4
Functions
10 ~
46
50 ~
114.8
Category
Health &
Air-purifying filter
Clean
10 ~
Photocatalytic deodorizing filter
46
Air-purifying filter with photocatalytic
50 ~
deodorizing function
114.8
Titanium apatite photocatalytic
air-purifying filter (option)
–15 ~
18
Air filter (prefilter)
Wipe-clean flat panel
5 ~
64.4
Washable grille
MOLD PROOF operation
Good-sleep cooling operation
Timer
WEEKLY TIMER
Count up-down ON/OFF timer
24-hour ON/OFF TIMER
NIGHT SET mode
Worry Free
Auto-restart (after power failure)
(Reliability &
Self-diagnosis (R/C, LED)
Durability)
Wiring error check function
Anti-corrosion treatment of outdoor heat
exchanger
Flexibility
Multi-split / split type compatible indoor
unit
H/P, C/O compatible indoor unit
Flexible power supply correspondence
Chargeless
Either side drain (right or left)
Power selection
Low temperature cooling operation
(–15°C) (5°F)
°F/°C changeover R/C temperature
display (factory setting: °F)
Remote
5-rooms centralized controller (option)
Control
Remote control adaptor
(normal open-pulse contact) (option)
Remote control adaptor
(normal open contact) (option)
DIII-NET compatible (adaptor) (option)
Remote
Wireless
Controller
Wired (option)
Split Type Air Conditioners FTK(X)-N Series
EDUS041502
Functions
32.8 ft
(10 m)
32.8 ft
(10 m)

Hide quick links:

Advertisement

Table of Contents
loading