Outdoor Unit - Daikin FTK09NMVJU Engineering Data

Cooling only / heat pump - seer 18 models
Hide thumbs Also See for FTK09NMVJU:
Table of Contents

Advertisement

EDUS041502
4.2

Outdoor Unit

RK09/12NMVJU, RX09/12NMVJU
DRAIN OUTLET
(I.D.φ5/8 (φ15.9mm) HOSE FOR CONNECTION
WITH DRAIN JOINT)
OUTDOOR AIR THERMISTOR
13/16 (20)
13/16 (20)
MINIMUM SPACE FOR AIR PASSAGE
1-15/16 (50)
UNIT: inch (mm)
RK18NMVJU, RX18NMVJU
HANDLE
9/16 ( 14 )
1/4 ( 7 )
12-5/8 ( 320 )
1-3/16 ( 30 )
4-HOLES FOR FOUNDATION BOLTS
( M8 OR M10 )
GROUND TERMINAL
SERVICE
PORT
6-13/16 ( 173 )
IN CASE OF REMOVING
STOP VALVE COVER AND
TERMINAL STRIP COVER
Split Type Air Conditioners FTK(X)-N Series
9/16 (15)
HANDLE
11-3/16 (284)
1/2 (12.4)
WALL HEIGHT ON AIR OUTLET SIDE
=LESS THAN 47-1/4 (1200)
1-15/16 (50)
1-15/16 (50)
34-1/4 ( 870 )
BRAND NAME PLATE
23-5/8 ( 600 )
LIQUID
20-11/16 ( 525 )
STOP VALVE
( φ1/4 ( φ6.4 ) CuT )
DRAIN OUTLET
GAS
( I.D.φ5/8 ( φ15.9 ) HOSE FOR
STOP VALVE
CONNECTION WITH DRAIN JOINT )
( φ1/2 ( φ12.7 ) CuT )
18-1/2 (470)
3-13/16 (97)
16-1/16 (408)
4-HOLES FOR FOUNDATION BOLTS
(M8 OR M10)
26-9/16 (675)
1-5/16 (50)
BRAND NAME PLATE
2-3/4 ( 70 )
ELECTRIC WIRE INTAKE
MANUFACTURER'S LABEL
9/16 ( 14.5 )
4-15/16 ( 125 )
13-5/8 ( 346 )
7/16 ( 11 )
( INSTALLATION LEG
PITCH )
14-1/2 ( 368 )
MINIMUM SPACE FOR AIR PASSAGE
1-15/16 ( 50 )
5/16 (8)
LIQUID
STOP VALVE
GROUND TERMINAL
(φ1/4 (φ6.4) CuT)
GAS
MANUFACTURER'S
STOP VALVE
LABEL
(φ3/8 (φ9.5) CuT)
SERVICE
PORT
6-1/4 (159)
IN CASE OF REMOVING
STOP VALVE COVER AND
TERMINAL STRIP COVER
OUTDOOR AIR THERMISTOR
3/4 ( 19 )
7/8 ( 23 )
WALL HEIGHT ON AIR OUTLET SIDE
=LESS THAN 47-1/4 ( 1200 )
1-15/16 ( 50 )
1-15/16 ( 50 )
UNIT: inch ( mm )
Dimensions
C: 3D092206
C: 3D092224
13