5.2

Error Codes and Diagnostic Codes

Blink
code
1
2
3
4
5
6
16
Fault
Consequence
for the Scooter
Battery must be
Continues to
charged
drive
Battery voltage too
Stops driving
low
Battery voltage too
Stops driving
high
Power time
Stops driving
exceeded
Brake failure
Stops driving
No neutral position
Stops driving
when switching
Scooter on.
Comments
·
The batteries are discharged. Charge the
battery as soon as possible.
·
The batteries are depleted. Charge
batteries.
·
If you switch the Scooter off for a few
minutes, the battery can often recuperate
to such a stage that a short journey is still
possible.
·
The battery voltage is too high. If the
battery charger is connected, disconnect
it from the Scooter.
·
The electronic system charges the
batteries when running downhill and
when braking. This fault is caused when
the battery voltage becomes too high
during this process. Switch the Scooter
off and on again.
·
The maximum current was exceeded
over too long a period, probably because
the motor was overloaded or has been
working against an immovable
resistance. Switch the scooter off, wait a
few minutes and then switch on again.
·
The electronic system has determined a
motor short-circuit. Check the wiring
harness for short-circuit and check the
motor.
·
Contact your Invacare® dealer.
·
Ensure that the disconnection lever is
pressed in.
·
There is a defect in the braking coil or in
the cabling. Check the magnetic brake
and cabling for open or short-circuited
circuitry. Contact your Invacare® dealer.
·
Drive lever is not in neutral when the
keyswitch was turned. Put the drive lever
in neutral, turn the power off and then
turn on again.
·
It may be necessary to recalibrate the
drive lever. Contact your Invacare®
dealer.
®
Invacare