a Extraction, recirculation with
conversion kit DUU 150.
b The wall unit housing needs to be
38 mm shorter than the wall unit
door.
c Installation is also possible in a
600 mm wide unit. In this case the
unit door must open upwards to
allow access to the grease filters.
This also applies for adjacent units.
d The ducting can also be connected
at the back.
e After installation, the wall unit can be
fitted with an interim panel. If this is
done, make sure that the slots for
the grease filters and, for the
charcoal filters in recirculation mode,
remain easily accessible.
f Alternatively, the wall unit can be
fitted with side sections.
The height of the wall unit and cut-out
dimensions must take account of any
accessories fitted, e.g. silencer, DSM
module.